Dresser Model 10C25 Series K Installation, Operation, and Maintenance Manual
© 2018 Natural Gas Solutions North America, LLC
Page 23 of 74
11.
Install the digital index onto the meter if it was
removed prior to AMR mounting (refer to Section
12.4.3).
12.
Install tamper evident devices, as applicable.
Figure 27: Attach digital index to meter
9.1.3
Using a Remote-Mounted AMR
If the AMR device is to be mounted remotely (not attached to the meter), perform the following steps:
1.
Push the AMR cable into the pulse output
connector until it locks into place.
Figure 28: Push the AMR cable into the pulse
output connector
2.
Align the remote AMR mounting bracket over the
holes on the top of the digital index.
This bracket helps prevent removal of the AMR
cable.
3.
Insert the screws into position and turn them until
they touch the cover.
4.
Tighten the screws to a maximum torque of 18 inch
pounds.
5.
Install tamper evident devices, as applicable.
Figure 29: Align and attach the remote AMR
mounting bracket to the digital index
The AMR device can now be installed in a location a distance from the meter. Verify the cable is long
enough to run from the AMR device location to the meter without tension.