12.
Carefully tuck the wires inside the digital index
housing.
13.
Carefully replace the digital index cover.
CAUTION
To prevent damage to the wires and the
seal, be careful not to pinch any of the
wires in between the cover.
Figure 55: Tuck in all wires and replace the
digital index cover (viewed from the top)
14.
After replacing the battery,
BATT. OK
displays
on the LCD screen if the battery and its wiring
connection are installed correctly.
The life of the battery is set to 240 months
(20 years). This can be verified by scrolling to
the
REM LIFE
LCD screen and viewing its value;
it should display
240MONTH
.
Figure 56: The battery is installed correctly
15.
Insert the four (4) screws into position, and
turn them until they touch the cover.
16.
Tighten the screws in a cross-pattern to a
maximum torque of 20 inch pounds.
17.
Install tamper evident devices as applicable.
Figure 57: Insert and tighten cover screws
12.7
Removing the Meter from Service
WARNING
If for any reason the meter must be removed from service after pressurizing the meter, strictly
adhere to safety precautions in accordance with established company and/or regulatory guidelines
and procedures.
Before working on the meter, slowly depressurize and vent all pressure from the meter. Release pressure
at a rate less than five (5) psig/second (35 kPa/second).
❶
❷
❸
❹