Dresser Model 10C25 Series K Installation, Operation, and Maintenance Manual
© 2018 Natural Gas Solutions North America, LLC
Page 44 of 74
10.
Lift the gasket and remove it around the digital
index cover by holding the gasket by the short
side and moving it over the cover.
The gasket can be maneuvered around the
digital index cover without disconnecting the
wires.
Figure 51: Remove the gasket
11.
Place and align a new gasket onto the digital
index housing. The gasket should lie flat.
CAUTION
To ensure a proper fit and seal, verify the
gasket is installed with the raised face side
of the gasket fitting into the groove around
the edge of the base (refer to Figure 54).
Figure 52: Closeup of gasket raised face side
Figure 53: Replace the gasket
Figure 54: Align the gasket in the index housing
with the raised face side up