Dresser Model 10C25 Series K Installation, Operation, and Maintenance Manual
© 2018 Natural Gas Solutions North America, LLC
Page 35 of 74
11.6.3
Audit Log
The Audit Log includes a tracking facility that details parameter changes that affect billing. The log
maintains the parameter change and its original information. Each entry is date and time stamped. The
Audit Log cannot be deleted.
The Audit Log is saved as a CSV (comma-separated values) file for easy import into spreadsheets, such as
Microsoft Excel. Download the Audit Log by using the
Logging
screen in the Dresser MeterWare software.
For more information, refer to the
Dresser MeterWare Software Manual
.
Changes recorded in the Audit Log include:
•
Parameters that have changed
•
Date and time the change occurred
•
Old value
•
New value
Parameters captured in the Audit Log include:
•
Meter Type
•
Pulse Output 1
•
Meter Size
•
Pulse Output 2
•
Revolution/Unit volume
•
Pulse Output 3
•
Flow Sense
•
Pulse Output 1 Selected
•
Temperature Units
•
Pulse Output 2 Selected
•
Base Temperature
•
Pulse Output 3 Selected
•
Temperature Mode
•
Telemetry Form A Pulse Width
•
Fixed Temperature
•
Compensated Volume
•
Pressure Units
•
Non-compensated Volume
•
Base Pressure
•
Non-compensated Volume Under Fault
•
Atmospheric Pressure
•
Pressure Calculation Type
•
Pressure Factor
•
User Temperature Calibration Offset
•
Fixed Pressure
•
High Temperature Alarm Limit
•
Pressure Mode
•
Low Temperature Alarm Limit
•
Compensated Multiplier
•
Volume Display Decimal Places
•
Non-compensated Multiplier
•
Corrected and Uncorrected Number of Digits