Dresser Model 10C25 Series K Installation, Operation, and Maintenance Manual
© 2018 Natural Gas Solutions North America, LLC
Page 69 of 74
Connecting with MeterWare
Perform the following steps to connect the meter to a computer to communicate with the MeterWare
software.
A.1
Required Equipment
The following equipment is needed to perform the steps in this section. Contact Customer Service to
request these parts or assistance:
•
Dresser MeterWare software installed
•
Dresser™ Communications Kit, which includes the parts listed in
Table 21: Communications Kit Contents
Item
Part
Purpose
1
USB extension cable
Connects
the IR dongle USB connector to the computer’s USB port
2
Magnet
Initializes and scrolls through LCD screens on the unit
3
IR dongle (with USB connection) Communicates with the IR window on the unit
4
IrDA cable holders
Aligns
the IrDA device with the unit’s IR window and hold
s it in
place
Figure 85: Communications Kit
Note:
The package or appearance of the items may differ from the ones shown in Figure 85.
For more information, refer to the
Dresser MeterWare Software Manual
.
❶
❷
❸
❹