Note:
Check remaining months of battery life by accessing the
REM LIFE
LCD screen.
12.6.1
Low Battery Indication
The meter monitors the state of the battery pack and generates a low battery alarm or fault before the
batteries are discharged. The period of time between the Low Battery Alarm and the Low Battery Fault is
approximately ninety (90) days.
Table 10: Low Battery Indicators
Battery Pack Voltage
Notice Generated
LCD Screen Display
Below 3 volts
Alarm
LBATT AL
Below 2.7 volts
Fault
LOW BATT
12.6.2
Battery Replacement
Perform the following steps to replace the sealed lithium battery pack in the digital index. Replace the
gasket to maintain the seal.
Table 11: Battery Replacement Parts Table
Part Description
Part Number
5/32 inch Allen wrench
-
Adjustable torque wrench/driver
-
Lithium battery pack
060416-000
Gasket
060309-000
Magnet
(or part of the Communications Kit)
060541-000
WARNING
All local codes shall be maintained during installation.
Batteries shall be:
•
Installed, put into service, used, and maintained in compliance with national and local regulations
and in accordance with the recommendations contained in the relevant standards concerning
potentially explosive atmospheres.
•
Installed by qualified and competent professionals who have undergone suitable training for
instrumentation used in areas with potentially explosive atmospheres.
Note:
The digital index does not need to be removed from the meter to replace the battery
pack.