8.3
Electronic Method
–
MeterWare Interface
The Leak Test feature is also accessible in the Dresser MeterWare software through the
Advanced
screen,
as shown in Figure 15.
This method requires connecting to the meter by using the IR (infrared) communication cable. The IrDA
cable refers to the IR dongle connected to the USB extension cable. For more information, refer to
Appendix A.
With the Dresser MeterWare software, you can adjust the test parameters and run the leak test (refer to
Figure 16).
After the leak test process completes, PASS or FAIL displays on the screen (refer to Figure 17) and on the
meter (as described in Section 8.2).
For more information about running a leak test by using the Dresser MeterWare interface, refer to the
Dresser MeterWare Software Manual
.
Figure 15: Advanced screen in Dresser MeterWare
Figure 16: Leak Test Parameters screen in
Dresser MeterWare
Figure 17: Leak test pass/fail indications in Dresser MeterWare