Dresser Model 10C25 Series K Installation, Operation, and Maintenance Manual
© 2018 Natural Gas Solutions North America, LLC
Page 56 of 74
The following tables provide information about filling in the data fields.
Table 15: Recommended Prover Configuration Settings
Meter
Differential
Flow Rate (% of Maximum Flow Rate)
100%
10%
Min. # of Pulses
Min. Test Volume
Min. # of Pulses
Min. Test Volume
1/2 inch w. c.
(0
–
1000 cfh)
10
10
2
2
Table 16: Prover Test Configuration Screen Settings
Data Field
Setting
Notes
Prover software configuration settings (
❶
)
Power Capacity
Select
10 M (10,000 cfh/283.2 m3/h)
.
For flow rates above 100 cfh
Select
2M (2,300 cfh/65.1 m3/h)
master meter.
For flow rates under 35 cfh and
100 cfh, if the prover is equipped with
this option
This setting allows for testing a meter
rated at 1/2 inch w.c. at 10% capacity
(100 cfh).
Figure 74: Prover configuration screen
Prover
software
configuration
settings
❶
TC Options
❷
Flow rate and
test points
❸
Prover test
start
❹