Criteria
Specification
Fault
Fault Conditions
•
Temperature
•
Volume
•
Low battery
•
Internal operation
Regulatory Standards
Regulatory Standards
•
ANSI, B109.3, LMB-EG-09E
•
OIML, MID, EN1359
•
EN 60529 for IP66 to IP68
•
EN 61000-6.1, 2, 3, 4
•
UN 38.3
•
060247-001 certificate of compliance
Safety Approvals
•
CSA C22.2 No. 213 Class 1 Div 1 Group A, B, C, D
•
T3C
Dust/Moisture Ingress Protection
IP66 to IP68 dependent upon connector configurations
Table 19: Temperature Accuracy
Temperature Range
Measurement Accuracy
-40°F to 32°F (-40°C to 0°C)
+/- 0.4°F (+/- 0.2°C)
32°F to 140°F (0°C to 60°C)
+/- 0.5°F (+/- 0.3°C)
18
Meter Capacity
Capacity of the 10C25 meter is not affected by specific gravity.
Table 20: Meter Capacity
Operating Pressure
Base Rating (cfh)
Corrected Capacity (scfh)
Base Rating (m
3
/h)
Corrected Capacity (nm
3
/h)
psig
kPa
bar
1000
28,3
0.25
1.7
0.02
1000
28,3
1
6.9
0.07
1045
29,6
3
20.7
0.21
1181
33,4
5
34.5
0.34
1317
37,3
10
68.9
0.69
1656
46,9
15
103.4
1.03
1996
56,5
20
137.9
1.38
2335
66,1
25
172.4
1.72
2675
75,7