176
TROUBLESHOOTING
The spout is bouncing
violently.
The hydraulic accumulator
has given away.
The control’s opening is
clogged.
Lower the spout and quickly stop it to check the
cylinder travel. If it’s less than 10 (3/8’’), replace
the actuator.
Remove the accumulator and check to make sure
the opening-plate located in its port is not clogged
by debris.
IMPORTANT
: Always lower the spout completely
before removing the accumulator (go around the
limit switch) - See the Maintenance/Adjustment
section.