7 - 2
Ultron DPM series
7.1 LCD Display Hierarchy
Main Screen
(Level 1)
UPS-1.1
Main Menu
(Level 1)
Login
(Level 1)
Event Log/ Warning
(Level 1)
EVENT LOG /
(Level 2)
(Level 2)
(Level 2)
(Level 3)
(Level 4)
Main Input
Measurement
UPS Setup
Maintenance
Line Voltage (V)
Phase Current (A)
Frequency (Hz)
Kilowatt-Hour (kWh)
Input Power Factor
(Level 3)
(Level 4)
Bypass Input
Line Voltage (V)
Frequency (Hz)
Temperature (°C)
(Level 3)
(Level 4)
Inverter Output
Line Voltage (V)
Phase Current (A)
Frequency (Hz)
(Level 3)
(Level 4)
UPS Output
Line Voltage (V)
Phase Current (A)
Frequency (Hz)
Load Total (%)
Apparent Power Total (KVA)
Active Power Total (KW)
Output CM Voltage
(Level 3)
(Level 4)
Battery Status
Voltage (V)
Current (A)
Remaining Capacity (%)
Remaining Time (mins)
Status
Battery Temperature
(Level 3)
(Level 4)
Bypass Setting
Voltage Range (Max)/ Voltage Range (Min)/
Frequency Range
(Level 3)
(Level 4)
Mode Setting
On-Line/ ECO
(Level 3)
(Level 4)
Output Setting
Voltage/ Frequency/ PM Redundancy/
Async Transfer Time/ DC to AC Delay Time/
Force Bypass to Inverter
(Level 3)
(Level 4)
Battery Setting
Battery Type/ Battery Rating Voltage/
Battery Capacity/ Battery Strings/
Battery Cut Off Voltage/ Installation Date/
Next Replacement Date/
Battery Charging Protection (IP DRY 2)/
Battery Fault Alarm (IP DRY 1)/
Battery Low Warning/ Battery Test Fail Voltage/
Battery Test Duration/ Auto Battery Test Interval/
Baseline Built for Aging Reference/
Aging Test Current
(Level 3)
(Level 4)
Charge Setting
Float Charge Volt/ Equalized Charge Volt/
Charge Current/ Auto Equalized Charge/
Auto Equalized Charge Period/
Auto Equalized Charge Time
(Level 3)
(Level 4)
Parallel Setting
Parallel Group ID/ Parallel ID/ Common Battery
(Level 3)
(Level 4)
Control
Buzzer/ Force Equalized Charge/
Reset Module/ Reset System
(Level 3)
(Level 4)
Test
Buzzer & LED Test / Battery Aging Test/
Manual Battery Test
(Level 3)
(Level 4)
Advanced Setting
OVAR Voltage Tolerance (max.)
OVAR Voltage Tolerance (min.)
(Level 3)
(Level 4)
General Setting
Date Format/ Date/ Time/
LCD Brightness/
LCD Sleep (after)/ Language
(Level 3)
(Level 4)
Other Setting
Serial COM ID/ Dust Filter Installation
*
1
/
Dust Filter Installation Date
*
1
/
Dust Filter Due Date
*
1
/ Admin Password
(Level 3)
Warning
(Level 3)
Historical Event
(Level 3)
Output Voltage
Abnormality Record
(Level 3)
(Level 4)
Statistics
Amount of Battery Mode Transition
Amount of Bypass Mode Transition
Operation time
(Level 3)
(Level 4)
Battery Discharging
History
Battery Discharge Curve
(Level 3)
(Level 4)
Clear
Clear Statistics/ Clear Historical Event/
Clear Output Voltage Abnormality Record/
Clear Kilowatt Hour (KW
·
h)
(Level 3)
(Level 4)
Advanced Diagnosis
DC BUS Voltage
PM A/D
PM D/D
Charge Voltage
Charge Current
(Level 3)
(Level 4)
Version
Touch Panel/ Rootfs/ System/
Power Module #/ Touch Panel FW Upgrade
(Level 3)
(Level 4)
Self-Diagnosis
System
STS Temperature (°C)
Ambient Temperature (°C)
Battery Temperature (°C)
Fan Speed (rpm)
Power Module #
DC CAP
AC CAP
IGBT
Fan Speed
(Level 3)
(Level 4)
IP Setting
DHCP Client
IP Address
Subnet Mask
Gateway IP
DNS 1 IP
DNS 2 IP
Search Domain
Host Name
*
1
*
1
*
1
*
1
*
1
*
1
*
1
*
1
*
1
*
1
*
1
*
1
*
1
*
1
(Figure 7-1: LCD Display Hierarchy)
Содержание Ultron DPM Series
Страница 12: ...1 6 Ultron DPM series 1 5 Standard Compliance UPS Capacity 1000kW 1250kW UL 1778...
Страница 38: ......
Страница 66: ......
Страница 232: ......
Страница 233: ...8 1 8 Optional Accessories 8 Optional Accessories...
Страница 235: ...9 1 9 Maintenance Maintenance 9...
Страница 243: ...10 Troubleshooting 10 1 Troubleshooting 10...
Страница 256: ......
Страница 257: ...A1 1 Appendix 1 7HFKQLFDO 6SHFL FDWLRQV Technical 6SHFL FDWLRQV A1...
Страница 260: ......
Страница 261: ...A2 1 Appendix 2 Warranty Warranty A2...
Страница 264: ......