VLT
®
FCD Series
Programming, FCD
300
621-642 Nameplate
Value:
Par.
no
Description
Nameplate
Display text
621
Unit type
(DRIVE TYPE)
624
Software version
(SOFTWARE VERSION)
625
LCP identification no.
(LCP VERSION)
626
Database identification no.
(DATABASE VER.)
627
Power parts version
(POWER UNIT DB ID)
628
Application option type
(APP. OPTION)
630
Communication option type
(COM. OPTION)
632
BMC software identification
(BMC-SOFTWARE ID)
634
Unit identification for communication
(UNIT ID)
635
Software parts no.
(SW. PART NO.)
640
Software version
(SOFTWARE VERSION)
641
BMC-software identification
(BMC2 SW)
642
Power card identification
(POWER ID)
Function:
The unit
’
s main data can be read out from parameters
621 to 635
Nameplate
using the LCP control unit or
serial communication. Parameters 640 - 642 can
also be seen on the unit
’
s integral display.
Description of choice:
Parameter 621 Nameplate: Unit type:
Gives unit size and mains voltage.
Example: FCD 311 380-480 V.
Parameter 624 Nameplate: Software version no.
The unit
’
s present software version number
appears here.
Example: V 1.00
Parameter 625 Nameplate: LCP ID number:
The ID number of the unit
’
s LCP appears here.
Example: ID 1.42 2 kB
Parameter 626 Nameplate: Database ID number:
The ID number of the software
’
s database
appears here.
Example: ID 1.14.
Parameter 627 Nameplate: Power section version:
The ID number of the unit
’
s power section appears here.
Example: ID 1.15.
Parameter 628 Nameplate: Application option type:
Here you can see which types of application options
are installed in the frequency converter.
Parameter 630 Nameplate: Communication
option type:
Here you can see which types of communication
options are installed in the frequency converter.
Parameter 632 Nameplate: BMC software
identification:
The ID number of the BMC software appears here.
Parameter 634 Nameplate: Unit identification
for communication:
The ID number for communication appears here.
Parameter 635 Nameplate: Software section no.:
The software section number appears here.
Parameter 640 Nameplate: Software version:
The unit
’
s present software version number
appears here. Example: 1.00
Parameter 641 Nameplate: BMC software
identification:
The ID number of the BMC software appears here.
Parameter 642 Nameplate: Power card identification:
The ID number of the unit
’
s power part appears
here.
Example: 1.15
✭
= factory setting. () = display text [] = value for use in communication via serial communication port
MG.04.B7.02 - VLT is a registered Danfoss trademark
99