VLT
®
FCD Series
Programming, FCD
300
Function:
See function description of parameter 502
Coasting stop.
Description of choice:
The table below shows which Setup (parameter
004
Active Setup
) is selected for each of the
following:
Digital input
[0],
Serial communication
[1],
Logic and
[2] or
Logic or
[3].
Digital input
[0]
Setup msb
Setup lsb
Function
0
0
Setup 1
0
1
Setup 2
1
0
Setup 3
1
1
Setup 4
Serial communication
[1]
Setup msb
Setup lsb
Function
0
0
Setup 1
0
1
Setup 2
1
0
Setup 3
1
1
Setup 4
Logic and
[2]
Bus Setup
msb
Bus
Setup
lsb
Dig.
Setup
msb
Dig.
Setup
lsb
Setup no.
0
0
0
0
1
0
0
0
1
1
0
0
1
0
1
0
0
1
1
1
0
1
0
0
1
0
1
0
1
2
0
1
1
0
1
0
1
1
1
2
1
0
0
0
1
1
0
0
1
1
1
0
1
0
3
1
0
1
1
3
1
1
0
0
1
1
1
0
1
2
1
1
1
0
3
1
1
1
1
4
Logic or
[3]
Bus
Setup
msb
Bus Setup
lsb
Dig.
Setup
msb
Dig.
Setup
lsb
Setup no.
0
0
0
0
1
0
0
0
1
2
0
0
1
0
3
0
0
1
1
4
0
1
0
0
2
0
1
0
1
2
0
1
1
0
4
0
1
1
1
4
1
0
0
0
3
1
0
0
1
4
1
0
1
0
3
1
0
1
1
4
1
1
0
0
4
1
1
0
1
4
1
1
1
0
4
1
1
1
1
4
508 Selection of preset ref.
(PRES.REF. SELECT)
Value:
Digital input (DIGITAL INPUT)
[0]
Serial comunication (SERIAL PORT)
[1]
Logic and (LOGIC AND)
[2]
✭
Logic or (LOGIC OR)
[3]
Function:
See function description of parameter 502
Coasting stop.
Description of choice:
Preset references via serial communication are
active when parameter 512
Telegram profile
is set to
FC protocol
[1].
509 Bus jog 1 (BUS JOG 1 FREQ.)
510 Bus jog 2 (BUS JOG 2 FREQ.)
Value:
0.0 - par. 202
Output frequency high limit
✭
10,0 Hz
Function:
If parameter 512
Telegram Profile
shows the selection
Profidrive
[0], two fixed speeds (Jog 1 or Jog 2)
can be selected via the serial port.
The function is the same as in parameter
213
Jog frequency
.
✭
= factory setting. () = display text [] = value for use in communication via serial communication port
MG.04.B7.02 - VLT is a registered Danfoss trademark
91