PNU
Parameter
Factory setting
Range
Change
s
4-Setup
Conver-
sion
Data
#
description
during operation
index
ype
600
Operating data: Operating hours
No
No
74
7
601
Operating data: Hours run
No
No
74
7
602
Operating data: kWh counter
No
No
3
7
603
Operating data: Number of cut-ins
No
No
0
6
604
Operating data: Number of overtemps
No
No
0
6
605
Operating data: Number of overvoltages
No
No
0
6
606
Data log: Digital input
No
No
0
5
607
Data log: Control word
No
No
0
6
608
Data log: Status word
No
No
0
6
609
Data log: Reference
No
No
-1
3
610
Data log: Feedback
No
No
-3
4
611
Data log: Output frequency
No
No
-1
3
612
Data log: Output voltage
No
No
-1
6
613
Data log: Output current
No
No
-2
3
614
Data log: DC link voltage
No
No
0
6
615
Fault log: Error code
No
No
0
5
616
Fault log: Time
No
No
0
7
617
Fault log: Value
No
No
0
3
618
Reset of kWh counter
No reset
Yes
No
0
5
619
Reset of hours-run counter
No reset
Yes
No
0
5
620
Operating mode
Normal function
Yes
No
0
5
621
Nameplate: Unit type
No
No
0
9
622
Nameplate: Power component
No
No
0
9
623
Nameplate: VLT ordering no.
No
No
0
9
624
Nameplate: Software version no.
No
No
0
9
625
Nameplate: LCP identification no.
No
No
0
9
626
Nameplate: Database identification no.
No
No
-2
9
627
Nameplate: Power component identification no.
No
No
0
9
628
Nameplate: Application option type
No
No
0
9
629
Nameplate: Application option ordering no.
No
No
0
9
630
Nameplate: Communication option type
No
No
0
9
631
Nameplate: Communication option ordering no.
No
No
0
9
655
Fault log: Real time
No
No
-4
7
Changes during operation:
"Yes" means that the parameter can be changed,
while the frequency converter is in operation. "No"
means that the frequency converter must be stopped
before a change can be made.
4-Setup:
"Yes" means that the parameter can be programmed
individually in each of the four setups, i.e. the same
parameter can have four different data values. "No"
means that the data value will be the same in all four
setups.
Conversion index:
This number refers to a conversion figure to be used
when writing or reading by means of a frequency con-
verter.
Conversion index
Conversion factor
74
0.1
2
100
1
10
0
1
-1
0.1
-2
0.01
-3
0.001
-4
0.0001
Data type:
Data type shows the type and length of the telegram.
Data type
Description
3
Integer 16
4
Integer 32
5
Unsigned 8
6
Unsigned 16
7
Unsigned 32
9
Text string
VLT
®
6000 HVAC Series
216
MG.61.B5.02 - VLT
®
is a registered Danfoss trademark
Содержание VLT 6000 HVAC Series
Страница 31: ...Ordering form VLT 6000 HVAC Series MG 61 B5 02 VLT is a registered Danfoss trademark 31 Introduction to HVAC ...
Страница 63: ...Mechanical dimensions VLT 6000 HVAC Series MG 61 B5 02 VLT is a registered Danfoss trademark 63 Installation ...
Страница 75: ...VLT 6000 HVAC Series MG 61 B5 02 VLT is a registered Danfoss trademark 75 Installation ...
Страница 204: ...VLT 6000 HVAC Series 204 MG 61 B5 02 VLT is a registered Danfoss trademark ...