009
Small display readout 1.2
(SMALL READOUT 2)
Value:
See parameter 007
Large display readout
Motorcurrent [A]
[5]
Function:
See the functional description for parameter 008
Small
display readout
. Data option
LCP display text
[29] can-
not be selected with
Small display readout
.
Description of choice:
There is a choice of 33 different data values, see pa-
rameter 007
Large display readout.
010
Small display readout 1.3
(SMALL READOUT 3)
Value:
Se parameter 007
Large display readout
Power [kW]
[6]
Function:
See the functional description for parameter 008
Small
data readout.
Data option
LCP display text
[29] cannot
be selected with
Small display readout
.
Description of choice:
There is a choice of 33 different data values, see pa-
rameter 007
Large display readout.
011
Unit of local reference
(UNIT OF LOC REF)
Value:
Hz (HZ)
[0]
% of output frequency range (%) (% OF
FMAX)
[1]
Function:
This parameter decides the local reference unit.
Description of choice:
Choose the required unit for local reference.
012
Hand start on LCP
(HAND START BTTN)
Value:
Disable (DISABLE)
[0]
Enable (ENABLE)
[1]
Function:
This parameter allows selection/deselection of the
Hand start key on the control panel.
Description of choice:
If
Disable
[0] is selected in this parameter, the [HAND
START] key will be inactive.
013
OFF/STOP on LCP
(STOP BUTTON)
Value:
Disable (DISABLE)
[0]
Enable (ENABLE)
[1]
Function:
This parameter allows selection/deselection of the lo-
cal stop key on the control panel.
Description of choice:
If
Disable
[0] is selected in this parameter, the [OFF/
STOP] key will be inactive.
NB!
If
Disable
is selected, the motor cannot be
stopped by means of the [OFF/STOP]
key.
014
Auto start on LCP
(AUTO START BTTN)
Value:
Disable (DISABLE)
[0]
Enable (ENABLE)
[1]
Function:
This parameter allows selection/deselection of the au-
to start key on the control panel.
Description of choice:
If
Disable
[0] is selected in this parameter, the [AUTO
START] key will be inactive.
VLT
®
6000 HVAC Series
= factory setting, () = display text, [] = value for use in communication via serial communication port
MG.61.B5.02 - VLT
®
is a registered Danfoss trademark
105
Pr
ogr
a
mmi
ng
Содержание VLT 6000 HVAC Series
Страница 31: ...Ordering form VLT 6000 HVAC Series MG 61 B5 02 VLT is a registered Danfoss trademark 31 Introduction to HVAC ...
Страница 63: ...Mechanical dimensions VLT 6000 HVAC Series MG 61 B5 02 VLT is a registered Danfoss trademark 63 Installation ...
Страница 75: ...VLT 6000 HVAC Series MG 61 B5 02 VLT is a registered Danfoss trademark 75 Installation ...
Страница 204: ...VLT 6000 HVAC Series 204 MG 61 B5 02 VLT is a registered Danfoss trademark ...