58
startup-alarm The method of sampling
variable Indicates the particular variable to be sampled
rmon alarm x falling-index y
command is used to set the Falling event
index of the alarm.
“
x
” is the index of the entry between 1~65535. “
y
” is
the Falling event index (1-65535).
rmon alarm x falling-threshold y
command is used to set the Falling
threshold value of the alarm.
“
x
” is the index of the entry between
1~65535. “
y
” is the Falling threshold value (-2147483648-2147483647).
rmon alarm x interval y
command is used to indicates the interval in
seconds for sampling and comparing the rising and falling threshold.
“
x
”
is the index
of the entry between 1~65535. “
y
” is the interval in seconds
between 1~2147483647.
rmon alarm x rising-index y
command is used to set the Rising event
index of the alarm.
“
x
” is the index of the entry between 1~65535. “
y
” is
the Rising event index (1-65535).
rmon alarm x rising-threshold y
command is used to set the Rising
threshold value of the alarm.
“
x
” is the index of the entry between
1~65535. “
y
” is the Rising threshold value (-2147483648-2147483647).
rmon alarm x sample-type [absolute | delta]
command is use to select the
method of sampling the selected variable and calculating the value to be
compared against the thresholds.
“
x
” is the index of the entry between
1~65535. The possible sample types are ...
-
absolute
: Get the sample directly.
-
delta
: Calculate the difference between samples.
rmon alarm x startup-alarm [falling | rising | risingorfalling]
command is
used to select the method of sampling the selected variable and
calculating the value to be compared against the thresholds.
“
x
” is the
index of the entry between 1~65535. The possible sample types are ...
- falling
: Trigger alarm when the first value is less than the falling
threshold.
-
rising
: Trigger alarm when the first value is larger than the rising
threshold.
-
risingorfalling
: Trigger alarm when the first value is larger than the rising
threshold or less than the falling threshold.
rmon alarm x variable .1.3.6.1.2.1.2.2.1.x.y
command is used to indicates
the particular variable to be sampled.
“
x
” is the index of the entry between
1~65535.“
y
” is 10~21. “
z
” is 1~65535.
Enter “rmon event x ?”. The commands for configiring pa rameters for the
event will be shown. “x” is the index of the entry. The range is from 1 to
65535.
For example, entering “rmon event 10 ?”, the follwing sub -commands
will be shown.
(config)# rmon event 10 ?
Содержание GSW-3208M1
Страница 1: ...1 GSW 3208M1 3216M1 3424M1 L2 Managed GbE Switches ...
Страница 176: ...173 ...
Страница 185: ...182 ...
Страница 202: ...199 This page is used to show the details of log Entering the ID details of the log will be shown ...
Страница 213: ...210 This page provides an overview of RMON Event table entries ...
Страница 215: ...212 This page provides an overview for LACP statistics for all ports ...
Страница 227: ...224 6 4 29 Monitor sFlow This page shows receiver and per port sFlow statistics ...
Страница 240: ......