log-level Log level
remote-log Enable logging to remote host
clear Clear logging table information
logging log-level x
command is used define the log level of events.
Indicates what kind of message will send to syslog server. Possible modes
are:
0: Info - Send informations, warnings and errors.
1: Warning - Send warnings and errors.
2: Error - Send errors.
The valid value
of “
x
” is 0~2.
logging remote-log
command is used to configure remote logging function.
Entering “logging remote-log ?”, the sub-commands will be shown.
(config)# logging remote-log ?
<1-1> Index
<cr>
logging remote-log
command is used to enable the remote logging
function. Events will be sent to syslog servers.
no logging remote-log
command is used to disable it.
logging remote-log x host y.y.y.y
command is used to set IP address
(y.y.y.y) to syslog server index x. One (
x
=1) syslog servers are supported.
“
y.y.y.y
” is the IPv4 host address of syslog server. If the switch provides
DNS feature, it also can be a host name.
logging clear
command is used to clear logging table information.
Entering “logging clear ?”, the sub-commands will be shown.
(config)# logging clear ?
<0-2> Logging level
<cr> All
logging clear x
command
is used to clear level “
x
” logging table
information. “
x
” is the logging level with value 0~2.
0: Info - informations, warnings and errors.
1: Warning - warnings and errors.
2: Error - errors.
logging clear
command is used to clear all logging table in formation.
21
loopback-detection
command
This command is used to configure loopback detection and protection
function of the switch globally. If loopback happens on any switch port,
packet storm could cause the switch fail to work. With this loopback
detection and protection function, port will be shutdown if loopback happens
on it. To implement this function, a loop protection PDU will be sent on each
port.
Entering “loopback-detection ?”, the sub-commands will be shown.
(config)# loopback-detection ?
Содержание GSW-3208M1
Страница 1: ...1 GSW 3208M1 3216M1 3424M1 L2 Managed GbE Switches ...
Страница 176: ...173 ...
Страница 185: ...182 ...
Страница 202: ...199 This page is used to show the details of log Entering the ID details of the log will be shown ...
Страница 213: ...210 This page provides an overview of RMON Event table entries ...
Страница 215: ...212 This page provides an overview for LACP statistics for all ports ...
Страница 227: ...224 6 4 29 Monitor sFlow This page shows receiver and per port sFlow statistics ...
Страница 240: ......