SM-Universal Encoder Plus User Guide
91
Issue Number: 6
www.controltechniques.com
Pr
x.28
defines the output mode for simulated encoder output as follows.
This position is taken from the position feedback device and is not affected by the
marker or the freeze inputs.
x.28
Encoder simulation mode
RW
Txt
US
Ú
0 to 7
Ö
0
Update rate: Background read
Pr x.28
String
Mode
0
Ab
Quadrature
1
Fd
Frequency and direction
2
SSI.Gray SSI output (Gray code)
3
SSI.Bin
SSI output (Binary format)
4
Ab.L
Quadrature with marker LOCK
5
Fd.L
Frequency and direction with marker LOCK
6
H.drv
Drive ABZ input signals routed through Hardware
7
H.int
Solutions Module ABZ input signals routed through Hardware
Modes 6 and 7 are only available with the drive software versions
01.07.00
onwards.
NOTE
If the source is not the feedback device, the simulator waits until all feedback devices
are initialised before the starting to output. The wait for initialisation does not occur if
the drive software version is less than
V01.08.00
.
NOTE
Also refer to section section 6.3
on page 45 for further
detailed information.
NOTE
x.29
Non-marker reset revolution counter
RO
Uni
NC
PT
Ú
0 to 65535 revolutions
Ö
Update rate: 4ms write
x.30
Non-marker reset position
RO
Uni
NC
PT
Ú
0 to 65535 (1/2
16
ths of a
revolution)
Ö
Update rate: 4ms write
x.31
Non-marker reset fine position
RO
Uni
NC
PT
Ú
0 to 65535 (1/2
32
nds of a
revolution)
Ö
Update rate: 4ms write