SM-Universal Encoder Plus User Guide
77
Issue Number: 6
www.controltechniques.com
Provided the set-up parameters for the position feedback are correct this parameter
shows the speed in rpm, this parameter is filtered to give a readable indication of speed.
Standard source for simulated encoder output with feedback position being updated
every 250
µ
s for the simulated encoder output. Pr
x.05
display value is updated every
4ms.
These parameters give the position with a resolution of 1/2
32
ths of a revolution as a 48
bit number as shown below.
Provided the set-up parameters are correct, the position is always converted to units of
1/2
32
ths of a revolution, but some parts of the value may not be relevant depending on
the resolution of the feedback device.
Example:
A 1024 line digital encoder produces 4096 counts per revolution, and so the position is
represented by the bits in the shaded area only.
When the feedback device rotates by more than one revolution, the revolutions in
Pr
x.04
increment or decrement in the form of a sixteen bit roll-over counter. If an
absolute position feedback is used the position is initialised at power-up with the
x.03
Speed
RO
Bi
FI
NC
PT
Ú
±40,000.0 rpm
Ö
Update rate: 4ms write
x.04
Revolution counter
RO
Uni
FI
NC
PT
Ú
0 to 65535 revolutions
Ö
Update rate: 4ms write
x.05
Position
RO
Uni
FI
NC
PT
Ú
0 to 65535
(1/2
16
ths of a revolution)
Ö
Update rate: 4ms write
x.06
Fine position
RO
Uni
FI
NC
PT
Ú
0 to 65535
(1/2
32
nds of a revolution)
Ö
Update rate: 4ms write
47 32
31 16
15 0
Revolutions
Position
Fine position
47 32
31 20 19 16
15 0
Revolutions
Position
Fine position
Содержание SM-Universal Encoder Plus
Страница 73: ...SM Universal Encoder Plus User Guide 73 Issue Number 6 www controltechniques com ...