3.2.1
Date code format
The date code is split into two sections: a letter followed by a number.
The letter indicates the year, and the number indicates the week number (within the
year) in which the Solutions Module was built.
The letters go in alphabetical order, starting with A in 1990 (B in 1991, C in 1992 etc.).
Example:
A date code of L35 would correspond to week 35 of year 2002.
3.3
Set-up parameters
All parameters associated to the SM-Universal Encoder Plus can be found in either
menu 15, 16, or 17. Each of menus 15, 16, and 17 refer to one of the available slots into
which the SM-Universal Encoder Plus can be fitted. See Figure 5-1 on page 24.
3.4
Compatible with encoder types
The SM-Universal Encoder Plus will allow for the following encoders to be used with
Unidrive SP:
3.4.1
Incremental encoders Ab, Fd, Fr and SC
These types of encoders give incremental position and can only be used for control in
Closed Loop Vector mode, or alternatively could be used for operation in servo mode. If
used in servo mode a phasing test is required at every power-up.
Quadrature detection logic determines rotation from the phase relationship of the two
channels.
These encoders are available with a marker pulse, which identifies each individual
rotation of the disc, and is also used to reset the drive position parameter. The
incremental encoder can be used when operating in Closed Loop Vector mode, with the
optional marker pulse not being required for correct operation.
SM-Universal
Encoder Plus
StdJ41
Ser No : 3000005001
Solutions Module
name
Customer
and date code
Serial number
Firmware
Firmware
04.xx.xx
Type
Encoder
Description
Pr x.15
Incremental
Ab
Quadrature incremental encoder.
With or without marker pulse.
0
Fd
Incremental encoder with frequency and direction outputs.
With or without marker pulse.
1
Fr
Incremental encoder with forward and reverse outputs.
With or without marker pulse.
2
SC
SinCos encoder with no serial communications
No optional marker pulse.
6
With this type of feedback the Unidrive SP must carry out a phasing test to find the phase
offset angle on power up for operation in servo mode.