Limitations
Type
Encoder
Max input frequency
Max no. of
lines
Max baud
rate
Linear
encoder
Ab
600kHz
50,000
Ab.SErvo
SC
115kHz (full resolution)
250kHz (reduced resolution)
SC.SErvo
SC.HiPEr
9600k
SC.EndAt
2Mbits/sec
SC.SSI
EndAt
SSI
In some applications using Closed Loop Vector control, the maximum speed of the
system is above the speed at which the encoder feedback frequency is too high to be
used by the drive. For these types of applications Pr
3.24
Closed Loop Vector Mode
should be set to 2 (Closed Loop Vector Mode with no maximum speed limit) for low
speed operation and 3 (Closed Loop Vector Mode without position feedback and with
no maximum speed limit) for high-speed operation. It should be noted that the drive no
longer checks that the maximum encoder frequency cannot be exceeded, and so the
user must ensure that Pr
3.24
is set to 3 before the encoder frequency limit is reached.
NOTE