92
SM-Universal Encoder Plus User Guide
www.controltechniques.com
Issue Number: 6
Each time the marker becomes active the non-marker position values (Pr
x.29
to
Pr
x.31
) are sampled and stored in Pr
x.32
to Pr
x.34
.
x.32
Marker revolution counter
RO
Uni
NC
PT
Ú
0 to 65535 revolutions
Ö
Update rate: 4ms write
x.33
Marker position
RO
Uni
NC
PT
Ú
0 to 65535 (1/2
16
ths of a
revolution)
Ö
Update rate: 4ms write
x.34
Marker fine position
RO
Uni
NC
PT
Ú
0 to 65535 (1/2
32
nds of a
revolution)
Ö
Update rate: 4ms write
x.35
Freeze revolution counter
RO
Uni
NC
PT
Ú
0 to 65535 revolutions
Ö
Update rate: 250
µ
s write
x.36
Freeze position
RO
Uni
NC
PT
Ú
0 to 65535 (1/2
16
ths of a
revolution)
Ö
Update rate: 250
µ
s write
x.37
Freeze fine position
RO
Uni
NC
PT
Ú
0 to 65535 (1/2
32
nds of a
revolution)
Ö
Update rate: 250
µ
s write
x.38
Freeze input mode/ Marker output select
RW
Uni
US
Ú
0 to 7
Ö
1
Update rate: Background read