106
SM-Universal Encoder Plus User Guide
www.controltechniques.com
Issue Number: 6
Simulated SSI encoder output (Binary or Graycode)
11.3
Drive encoder power supply
Common to all Encoder types
The encoder supply voltage is controlled by Pr
x.13
. The default for this parameter is 5V
(0) but this can be set to 8V (1) or 15V (2). Setting the encoder voltage supply too high
for the encoder could result in damage to the feedback device.
The termination resistors should be disabled if the outputs from the encoder are higher
than 5V.
7
Data (output)
8
Data\ (output)
9
Clock\ (input)
10
Clock (input)
Type
EIA 485 differential transceivers
Maximum frequency
Limited to 500kHz (output frequency set by
master)
Line loading
32 unit loads (for terminals 5 and 6)
1 unit load (for terminals 11 and 12)
Working common mode range
+12V to –7V
Absolute maximum applied voltage relative to
0V
±
14V
Absolute maximum applied differential voltage
±
14V
13
Encoder supply voltage
Supply voltage
5V, 8V or 15V
Maximum output current
300mA for 5V and 8V
200mA for 15V
14
0V common
15
Motor thermistor input
Short circuit trip level
<50
Ω
±
30%
Over temperature trip level
<3k3
Ω
±
10%
Reset level
>3k3
Ω