54
SM-Universal Encoder Plus User Guide
www.controltechniques.com
Issue Number: 6
Figure 6-1
SM-Universal Encoder Plus to SM-Applications freeze transfer
6.6.3
Freeze input with SM-Encoder Plus and SM-Resolver
Before consecutive freeze operations can be performed in the SM-Encoder Plus or SM-
Resolver, the SM-Universal Encoder Plus freeze flag (Pr
x.39
), or SM-Applications
freeze flag (Pr
90.18
and Pr
90.28
) must be cleared together with the SM-Encoder Plus
and SM-Resolver freeze flag (Pr
x.39
).
A
Freeze input active anywhere within 250
µ
s
B
Freeze positional data available in SM-Universal Encoder Plus
C
90
µ
s delay before SM-Applications can use data
D
Data available for SM-Applications, plus freeze unlatch sent to SM-Universal Encoder Plus
E
Freeze input unlatched anywhere with 90
µ
s by SM-Universal Encoder Plus
F
Freeze input unlatched
Datum
Freeze input
SM-Universal
Encoder Plus
SM-Applications
Freeze unlatched
250 s
µ
160 s
µ
A
B
C
340 s
µ
Maximum delay for freeze data to
be available to SM-Applications
590 s
µ
Maximum delay to 2nd freeze input being
detected by SM-Universal Encoder Plus
Maximum latch delay = 200ns for freeze input to be detected
D
E
90 s
µ
90 s
µ
F