108
SM-Universal Encoder Plus User Guide
www.controltechniques.com
Issue Number: 6
Simulated SSI encoder output (Binary or Graycode)
3
Data (output)
4
Data\ (output)
5
Clock\ (input)
6
Clock (input)
Type
EIA 485 differential transceivers
Maximum frequency
Limited to 500kHz (output frequency set by
master)
Line loading
32 unit loads (for terminals 5 and 6)
1 unit load (for terminals 11 and 12)
Working common mode range
+12V to –7V
Absolute maximum applied voltage relative to
0V
±
14V
Absolute maximum applied differential voltage
±
14V
The simulated encoder outputs available on terminal PL1 are identical to the simulated
encoder outputs available on terminal SK2 (internally connected)