Figure 5-4
Fitting of grounding bracket (sizes 1 to 6)
Loosen the ground connection nuts and slide the grounding bracket in the direction
shown. Once in place, re-tighten the ground connection nuts.
A faston tab is located on the grounding bracket for the purpose of connecting the drive
0V to ground should the user require to do so.
When a Unidrive SP size 4 or 5 is through-panel mounted, the grounding link bracket
must be folded upwards. A screw can be used to secure the bracket or it can be located
under the mounting bracket to ensure that a ground connection is made. This is
required to provide a grounding point for the grounding bracket as shown in Figure 5-4.
On Unidrive SP size 1 and 2, the grounding bracket is secured using the power ground
terminal of the drive. Ensure that the supply ground connection is secure after fitting /
removing the grounding bracket. Failure to do so will result in the drive not being
grounded.