SM-Universal Encoder Plus User Guide
13
Issue Number: 6
www.controltechniques.com
Figure 3-6 Example of encoder feedback signals
* Max input frequency = LPR x max rpm / 60
In Ab.SErvo, Fd.SErvo or Fr.SErvo mode only, the value in Pr
x. 42
provides information
on the commutation signal inputs (UVW). Pr x.42 permits the user to determine the
current segment and status of the commutation signal inputs.
For further details refer to Pr
x.42
NOTE
Limitations
Type
Encoder
Max Input Frequency
Max no. of
Lines (LPR)
Incremental
plus
commutation
Ab.SErvo
600kHz*
50,000
Fd.SErvo
Fr.SErvo
SC.SErvo
115kHz* (full resolution)
250kHz (reduced resolution)
Incremental
signals
360 electrical degrees (encoder)
°
90 separation of A and B
°
Index
alignment
reference
1
/
3
1
/
2
2
/
3
1
Mechanical revolution
A
/A
B
/B
Z
/Z
U
V
W
Marker
signals
Commutation
signals
min
max