104
SM-Universal Encoder Plus User Guide
www.controltechniques.com
Issue Number: 6
11
Terminal Data
For location of terminals refer to Figure 3-2
SM-Universal Encoder Plus connectors
11.1
Encoder inputs SK2
Ab, Fd, Fr, Ab.SErvo, Fd.SErvo, Fr.SErvo and SC.SErvo encoders
SC, SC.SErvo, SC.HiPEr, SC.EndAt and SC.SSI encoders
1
Channel A, Frequency or Forward
2
Channel A\, Frequency\ or Forward\
3
Channel B, Direction or Reverse
4
Channel B\, Direction\ or Reverse\
5
Marker pulse channel Z
6
Marker pulse channel Z\
7
Phase channel U
8
Phase channel U\
9
Phase channel V
10
Phase channel V\
11
Phase channel W
12
Phase channel W\
Type
EIA 485 differential receivers
Maximum frequency
600kHz
Line loading
<2 unit loads (for terminals 1 to 4)
32 unit loads (for terminals 5 and 6)
1 unit load (for terminals 7 to 12)
Line termination components
120
Ω
Working common mode range
+12V to –7V
Absolute maximum applied voltage relative to
0V
+
14V to -9 (u, v, w, z)
±
25V (Ab, Fd, Fr)
Absolute maximum applied differential voltage
+
14V to -9 (u, v, w, z)
±
25V (Ab, Fd, Fr)
1
Channel Cos
2
Channel Cosref
3
Channel Sin
4
Channel Sinref
Type
Differential voltage
Maximum signal level
1.25V peak to peak
Maximum frequency
115kHz (250kHz with lower resolution. See Pr
Maximum applied differential voltage
±
1.5V