Chapter 2 Installing the IDS-4210
Upgrading the Memory
2-4
Cisco Intrusion Detection System Appliance and Module Installation and Configuration Guide Version 4.1
78-15597-02
See
Working in an ESD Environment, page 1-21
, for more information.
Step 6
Remove the chassis cover by unscrewing the screw(s) on the front of the cover and
sliding the cover straight back.
Note
IDS-4210 sensors have a single screw on the front cover. IDS-4220
sensors have three screws spaced evenly across the front cover.
Step 7
Locate the DIMM sockets and select an empty DIMM socket next to the existing
DIMM.
Note
On IDS-4210 sensors, the existing DIMM is installed in socket 0. The
angled position of the DIMM sockets make installing an additional
DIMM in socket 1 difficult if a DIMM occupies socket 0. Therefore, you
should first remove the existing DIMM from socket 0, place the new
DIMM in socket 1, and then place the existing DIMM back in socket 0.
Step 8
Locate the ejector tabs on either side of the DIMM socket. Press down and out on
tabs to open the slot in the socket.
Bank 3
41167
DIMM
Bank 0
Bank 2
Bank 1