Chapter 8 Installing the IDSM-2
Installation and Removal Instructions
8-10
Cisco Intrusion Detection System Appliance and Module Installation and Configuration Guide Version 4.1
78-15597-02
Step 8
Using the thumb and forefinger of each hand, simultaneously pivot in both ejector
levers to fully seat the IDSM-2 in the backplane connector.
Caution
Always use the ejector levers when installing or removing the IDSM-2. A module
that is partially seated in the backplane causes the system to halt and subsequently
crash.
Note
If you perform a hot swap, the console displays the message “Module x
has been inserted.” This message does not appear, however, if you are
connected to the Catalyst 6500 series switch through a Telnet session.
Step 9
Use a screwdriver to tighten the installation screws on the left and right ends of
the IDSM-2.
Step 10
Verify that you have correctly installed the IDSM-2 and can bring it online. See
Verifying the IDSM-2 Installation, page 8-11
, for the procedure.
Step 11
Initialize the IDSM-2.
See
Initializing the Sensor, page 10-2
, for the procedure.