Chapter 10 Configuring the Sensor Using the CLI
IDSM-2 Configuration Tasks
10-104
Cisco Intrusion Detection System Appliance and Module Installation and Configuration Guide Version 4.1
78-15597-02
•
set port name module_number
Configures the name for the specified IDSM-2 port.
•
set span
Configures port 1 as a SPAN destination port. You cannot use port 1 on the
IDSM-2 as a SPAN source port.
•
set trunk
Configures trunk ports.
•
set vlan
Configures VLAN capture ports.
•
show config
Displays the supervisor engine NVRAM configurations.
•
show log
Displays the error logs for the specified IDSM-2.
•
show mac module_number
Displays the MAC counters for the specified IDSM-2.
•
show module module_number
With an IDSM-2 installed, displays “Intrusion Detection System Module”
under Module-Type.
•
show port module_number
Displays the port status for the specified IDSM-2.
•
show port capabilities [module | module_number]
Displays the capabilities of the module and ports.
•
show test
Displays the errors reported from the diagnostic tests for both the SPAN port
(port 1) and the management port (port 2) and the BIOS and CMOS boot
results.