Chapter 5 Installing the IDS-4235 and IDS-4250
Installing the Accessories
5-28
Cisco Intrusion Detection System Appliance and Module Installation and Configuration Guide Version 4.1
78-15597-02
Step 8
Press the slide release latch at the side of each latch to slide the appliance
completely into the rack (see
Figure 5-7 on page 5-27
).
Step 9
Push in and turn the captive thumbscrews on each side of the front chassis panel
to secure the appliance to the rack.
Installing the Cable-Management Arm
You can install the cable-management arm on the right or left of the rack cabinet.
This procedure describes installing the cable-management arm in the right side of
the rack cabinet, as viewed from the back.
Tip
If you are installing several appliances in the rack, consider installing the cable
management arms on alternating sides of the rack for ease in cable routing.
To install the cable-management arm, follow these steps:
Step 1
Facing the back of the rack cabinet, locate the latch on the end of the right slide
assembly that you secured to the back vertical rail.
Step 2
Push the tab on the back end of the cable-management arm into the latch on the
end of the slide assembly (see
Figure 5-8 on page 5-29
).
Note
The latch clicks when locked.
Step 3
Push the tab on the remaining free end (the front) into a mating latch on the inner
segment of the slide assembly (see
Figure 5-8 on page 5-29
).
Note
The latch clicks when locked.
Step 4
Install a stop block on the latch on the end of the opposite slide assembly (see
Figure 5-8 on page 5-29
).