A-27
Cisco Intrusion Detection System Appliance and Module Installation and Configuration Guide Version 4.1
78-15597-02
Appendix A Intrusion Detection System Architecture
System Components
Blocking with the Catalyst 6000
A Catalyst 6000 switch with a PFC card filters packets using VACLs. VACLs filter
all packets between VLANs and within a VLAN.
MSFC router ACLs are supported when WAN cards are installed and you want the
sensor to control the interfaces through the MSFC2.
Note
An MSFC2 card is not a required part of a Catalyst 6000 configuration for
blocking with VACLs.
Caution
When you configure NAC for the Catalyst 6000, do not specify a direction with
the controlled interface. The interface name is a VLAN number. Preblock and
postblock lists should be VACLs.
The following commands apply to the Catalyst 6000 VACLs:
•
To view an existing VACL:
show security acl info {
aclname
}
•
To block an address (address spec is the same as used by router ACLs):
set security acl ip {
aclname
} deny {
address spec
}
•
To activate VACLs after building the lists:
commit security acl all
•
To clear a single VACL:
clear security acl map {
aclname
}
•
To clear all VACLs:
clear security acl map all
•
To map a VACL to a VLAN:
set sec acl {
aclname
} {
vlans
}
See
Configuring Blocking Devices, page 10-67
, for more information.