Appendix B Troubleshooting
Troubleshooting the 4200 Series Appliance
B-8
Cisco Intrusion Detection System Appliance and Module Installation and Configuration Guide Version 4.1
78-15597-02
Step 2
Verify that the Web server is still running:
a.
Use the show version command to check the status of the WebServer:
sensor# show version
Application Partition:
Cisco Systems Intrusion Detection Sensor, Version 4.1(3)S61
OS Version 2.4.18-5smpbigphys
Platform: IDS-4235
Sensor up-time is 20 days.
Using 214319104 out of 921522176 bytes of available memory (23% usage)
Using 596M out of 15G bytes of available disk space (5% usage)
MainApp 2003_Oct_10_11.16 (Release) 2003-10-10T11:01:13-0500 Running
AnalysisEngine 2003_Oct_10_11.16 (Release) 2003-10-10T11:01:13-0500 Running
Authentication 2003_Oct_10_11.16 (Release) 2003-10-10T11:01:13-0500 Running
Logger 2003_Oct_10_11.16 (Release) 2003-10-10T11:01:13-0500 Running
NetworkAccess 2003_Oct_10_11.16 (Release) 2003-10-10T11:01:13-0500 Running
TransactionSource 2003_Oct_10_11.16 (Release) 2003-10-10T11:01:13-0500 Running
WebServer 2003_Oct_10_11.16 (Release) 2003-10-10T11:01:13-0500 Running
CLI 2003_Oct_10_11.16 (Release) 2003-10-10T11:01:13-0500
WebServer 2003_Oct_10_11.16 (Release) 2003-10-10T11:01:13-0500 Running
CLI 2003_Oct_10_11.16 (Release) 2003-10-10T11:01:13-0500
Upgrade History:
* IDS-K9-min-4.1-1-S47 12:00:00 UTC Thu Jun 30 2005
IDS-K9-sp-4.1-3-S61.rpm.pkg 14:14:55 UTC Fri Feb 20 2004
Recovery Partition Version 1.2 - 4.1(1)S47
The Web server is still running. Go to Step 4
b.
The web server is still not running:
sensor# show version
Application Partition:
Cisco Systems Intrusion Detection Sensor, Version 4.1(3)S61
OS Version 2.4.18-5smpbigphys
Platform: IDS-4235
Sensor up-time is 20 days.
Using 214319104 out of 921522176 bytes of available memory (23% usage)
Using 596M out of 15G bytes of available disk space (5% usage)