Chapter 10 Configuring the Sensor Using the CLI
IDSM-2 Configuration Tasks
10-100
Cisco Intrusion Detection System Appliance and Module Installation and Configuration Guide Version 4.1
78-15597-02
To enable a full memory test, follow these steps:
Step 1
Log in to the console.
Step 2
Type the following commands:
Console> set boot device cf:1 4
mem-test-full
Console> show boot device 4
The set boot device command can either contain cf:1 or hdd:1.
The following output appears:
Device BOOT variable = cf:1
FAST BOOT Enabled
Step 3
Reset the IDSM-2.
See
Resetting the IDSM-2, page 10-101
, for the procedure.
The full memory test runs.
Note
A full memory test takes more time to complete than a partial memory
test.
Cisco IOS Software
You can enable a full memory test when you use the set boot device bootseq
module_number mem-test-full command. The long memory test takes about 12
minutes.
To enable a full memory test, follow these steps:
Step 1
Log in to the console.
Step 2
Type the following commands:
Router# set boot device cf:1 4 mem-test-full
Router# show boot device 4
The set boot device command can either contain cf:1 or hdd:1.
Содержание IDS-4230-FE - Intrusion Detection Sys Fast Ethernet Sensor
Страница 4: ......
Страница 450: ...Appendix B Troubleshooting ...