A-9
Cisco Intrusion Detection System Appliance and Module Installation and Configuration Guide Version 4.1
78-15597-02
Appendix A Intrusion Detection System Architecture
System Components
•
Schedule, download, and install software upgrades.
Note
The legacy application is idsupdate.
•
Configure the communications network interface.
MainApp sets the hostname, IP address, netmask, and default gateway for the
sensor’s command and control interface. It also configures the network access
list.
Note
The legacy application is sysconfig-sensor.
•
Manage the system clock.
There are three clock management modes:
–
NTP—Uses an NTP server to synchronize the sensor’s clock.
–
Manual—Used only on the appliance, this mode relies on the sensor’s
system clock.
–
Switch/Router—Used only on the IDSM-2 and the NM-CIDS.
The IDSM-2 uses switch control protocol to synchronize its clock with
the switch supervisor’s clock. The NM-CIDS uses router/blade control
protocol to synchronize its clock to the parent router’s clock.
Note
We recommend that you use NTP time because it is more reliable.
See
Setting the Time on Sensors, page 1-18
. for more
information.
•
Shut itself down and cleanly shut down all IDS components and applications.
MainApp shuts itself and all IDS components and applications down in the
following sequence:
1.
Deregister control transaction requests.
2.
Stop the update scheduler.
3.
Open evStatus event subscription.