Appendix B Troubleshooting
Troubleshooting the IDSM-2
B-50
Cisco Intrusion Detection System Appliance and Module Installation and Configuration Guide Version 4.1
78-15597-02
Step 4
Make sure the command and control port is in the correct VLAN:
For Catalyst software:
console> (enable) show port 9/2
* = Configured MAC Address
Port Name Status Vlan Duplex Speed Type
----- ------------ ---------- ------- ------ --------- ------------
9/2 connected 146 full 1000 Intrusion De
Port Broadcast-Limit Multicast Unicast Total-Drop Action
----- --------------- --------- ------- -------------- ------------
9/2 - - - 0 drop-packets
Port Status ErrDisable Reason Port ErrDisableTimeout Action on Timeout
---- ---------- ------------------ ---------------------- -----------------
9/2 connected - Enable No Change
Port Align-Err FCS-Err Xmit-Err Rcv-Err UnderSize
----- ---------- ---------- ---------- ---------- ---------
9/2 0 0 0 0 0
Port Single-Col Multi-Coll Late-Coll Excess-Col Carri-Sen Runts Giants
----- ---------- ---------- ---------- ---------- --------- --------- ---------
9/2 0 0 0 0 0 0 0
Port Last-Time-Cleared
----- --------------------------
9/2 Mon Jul 19 2004, 09:58:55
Idle Detection
--------------
--
console> (enable)
For Cisco IOS software:
router# show intrusion-detection module 6 management-port state
Intrusion-detection module 6 management-port:
Switchport: Enabled
Administrative Mode: dynamic desirable
Operational Mode: static access
Administrative Trunking Encapsulation: negotiate
Operational Trunking Encapsulation: native
Negotiation of Trunking: On