8-13
Cisco Intrusion Detection System Appliance and Module Installation and Configuration Guide Version 4.1
78-15597-02
Chapter 8 Installing the IDSM-2
Installation and Removal Instructions
Mod Online Diag Status
--- -------------------
1 Pass
2 Pass
5 Pass
6 Not Supported
7 Not Supported
9 Pass
router#
Note
It is normal for the status to read “other” when the IDSM-2 is first
installed. After the IDSM-2 completes the diagnostics routines and comes
online, the status reads “ok.” Allow up to 5 minutes for the IDSM-2 to
come online.
See
Enabling a Full Memory Test, page 10-99
, for information on enabling a full
memory test after verifying the IDSM-2 installation.
Removing the IDSM-2
This procedure describes how to remove the IDSM-2 from the Catalyst 6500
series switch.
Warning
Only trained and qualified personnel should be allowed to install, replace, or
service this equipment. Statement 1030
Caution
Before removing the IDSM-2, be sure to perform the shutdown procedure. If the
IDSM-2 is not shut down correctly, you could corrupt the software.
Warning
During this procedure, wear grounding wrist straps to avoid ESD damage to the
card. Do not touch the backplane with your hand or any metal tool, or you could
shock yourself.