Chapter 14
14-26
[ Inspected by Canon Inc. ]
Description
As a result of inspection, the following was found: When an A3-size original with sharp folds is set in the document feeder (DF), the machine detects it as
A4-size and scans the corresponding area. This is because the latter half of the original is folded and fails to come into contact with the document length
sensor flag on the DF, consequently preventing the length sensor from detecting the original as large size.
When scanning an original with sharp folds from the DF, remove the folds or place it on the copyboard glass. Moreover, the use of the Preview button on the
LCD before scanning enables you to check whether the full image of the original is scanned. Please explain these to your customer.
14.2.5.1.2 Machine does not send E-mail
0010-4397
iR2270 / iR2870 / iR3570 / iR4570 / / / / / iR2230 / / / iR3530 / / / /
[ Case in the field ]
Description
In the field, the symptom occurred because the host name and the domain name were not registered in user mode [System Settings > Network Settings > TCP/
IP Settings > DNS Server Settings].
Field Remedy
When the symptom occurs, enter user mode [System Settings > Network Settings > TCP/IP Settings > DNS Server Settings], and enter the name assigned to
this machine as the host name and the name of network domain to which this machine belongs as the domain name.
14.2.5.1.3 Machine hangs up during FAX transmission: Because read sensor (PI3) of DADF-N1 is not snapped securely
0010-8165
iR2270 / iR2870 / iR3570 / iR4570 / / iR2270N / / iR2870N / / iR3570N / / iR4570N / iR2230 / / / iR3530 / / / / / / /
[ Inspected by Canon Inc. ]
Description
When running a FAX transmission job consisting of 20 sheets of A4-size originals using the DADF-N1, the leading edge of an original stopped at the original
reading position, and then the machine hung up. This was because the read sensor (PI3) of the DADF chattered. This is for your information, but if the claws
of PI3 are not snapped securely into the mount, the sensor may chatter.
Field Remedy
When the symptom has occurred, snap the sensor into the mount again.
WG8-5624 Photointerrupter (PI3)
14.2.5.2 Other Operational Defect
14.2.5.2.1 LCD on control panel responds slowly: Because numbers of destinations are registered
0010-4392
iR2270 / iR2870 / iR3570 / iR4570 / / / / / iR2230 / / / iR3530 / / / /
[ Verified by Canon Inc. ]
Description
When 178 destinations were registered in the one-touch buttons, 780 destinations in the address book, and 78 destinations as the forwarding settings, the LCD
on the control panel responded slowly. As the measure for this symptom, system software version 8.02 was released.
Field Remedy
When the symptom occurs, upgrade system software to version 8.02 or later.
14.2.5.2.2 DADF-N1: Stamp is not printed when sending FAX message because solenoid connector has poor connection
0010-4394
iR2270 / iR2870 / iR3570 / iR4570 / / / / / iR2230 / / / iR3530 / / / /
[ Case in the field ]
Field Remedy
In the field, a stamp was not printed when a document was scanned for FAX transmission. This was because the connector (J14) of the solenoid (SL2) had
poor connection. When the symptom has occurred, execute the following in service mode:
[FEEDER > FUNCTION > SL-CHK > enter "1" > OK > SL-ON > OK].
If the operating sound of the solenoid is not heard, reinsert the connector J14.
14.2.6 Jam (Main Unit)
14.2.6.1 0105 Jam Code: Occurs only at pickup from cassette 1 because right lower door sheet is faulty
0011-6437
iR2270 / iR2870 / iR3570 / iR4570 / / iR2270N / / iR2870N / / iR3570N / / iR4570N / iR2230 / / / iR3530 / / / / / / /
[ Case in the field ]
Description
In the field, the right lower door sheets were affixed askew to the inside of both upper ends of the right lower door that accompany the paper pick-up assembly
for the cassette 2, leading to 0105 Jam every time paper was fed from the cassette1.
Field Remedy
When a right lower door sheet is attached askew, re-fit it. If it is deteriorated, replace it with a new one.
FC5-7413 Right Lower Door Sheet
14.2.6.2 0207 Jam Code: Because solenoid (SL1) does not work on account of defective delivery controller PCB
0010-6519
iR2270 / iR2870 / iR3570 / iR4570 / / iR2270N / / iR2870N / / iR3570N / / iR4570N / iR2230 / / / iR3530 / / / / /
[ Case in the field ]
Description
In the field, the solenoid (SL1) of the 1st delivery flapper (FL2-1212) did not work, and as a result, a paper jam occurred at the delivery assembly when
making copies continuously. However, this symptom was solved by replacing the delivery controller PCB with a new one.
- 0207 Jam Code: Stationary jam at the fixing/delivery sensor (PS13).
Field Remedy
1. Service mode > COPIER > FUNCTION > PART-CHK > set [SL] to "7" (SL1 operation code) > OK > SL-ON > OK. This setting will make the machine
turn the SL1 ON and then OFF three times. On this occasion, check if the SL1 makes operating sound.
2. When executing [SL-ON] in service mode, if the indication on the LCD changes in the following order: START > ACTIVE > OK!, and no operating sound
occurs, check if the SL1 has electrical continuity.
3. If the SL1 have electrical continuity, re-insert the delivery controller PCB connectors, and then execute Step 1 again.
4. If the SL1 still makes no operating sound, replace the delivery controller PCB with a new one.
FM2-3221 Delivery Controller PCB Assembly
Содержание iR3570 Series
Страница 1: ...Jan 17 2007 Service Manual iR4570 3570 2870 2270 Series...
Страница 2: ......
Страница 6: ......
Страница 27: ...Chapter 1 Introduction...
Страница 28: ......
Страница 70: ......
Страница 71: ...Chapter 2 Installation...
Страница 72: ......
Страница 146: ......
Страница 147: ...Chapter 3 Basic Operation...
Страница 148: ......
Страница 150: ......
Страница 154: ......
Страница 155: ...Chapter 4 Main Controller...
Страница 156: ......
Страница 187: ...Chapter 5 Original Exposure System...
Страница 188: ......
Страница 217: ...Chapter 5 5 27 F 5 91...
Страница 218: ......
Страница 219: ...Chapter 6 Laser Exposure...
Страница 220: ......
Страница 222: ......
Страница 230: ......
Страница 231: ...Chapter 7 Image Formation...
Страница 232: ......
Страница 236: ......
Страница 279: ...Chapter 7 7 43 F 7 241 2 Remove the screw 1 F 7 242 3 Detach the static eliminator 1 to the front F 7 243...
Страница 280: ......
Страница 281: ...Chapter 8 Pickup Feeding System...
Страница 282: ......
Страница 388: ......
Страница 389: ...Chapter 9 Fixing System...
Страница 390: ......
Страница 419: ...Chapter 9 9 27 F 9 148...
Страница 420: ......
Страница 421: ...Chapter 10 External and Controls...
Страница 422: ......
Страница 426: ......
Страница 437: ...Chapter 10 10 11 F 10 12 2 Remove the check mark from SNMP Status Enabled...
Страница 438: ...Chapter 10 10 12 F 10 13...
Страница 440: ...Chapter 10 10 14 F 10 15...
Страница 475: ...Chapter 11 MEAP...
Страница 476: ......
Страница 478: ......
Страница 481: ...Chapter 12 Maintenance and Inspection...
Страница 482: ......
Страница 484: ......
Страница 509: ...Chapter 13 Standards and Adjustments...
Страница 510: ......
Страница 512: ......
Страница 521: ...Chapter 14 Correcting Faulty Images...
Страница 522: ......
Страница 528: ......
Страница 537: ...Chapter 14 14 9 43mm s b Z x i j B iR4570_395 s u A B FM2 0287...
Страница 538: ...Chapter 14 14 10...
Страница 539: ...Chapter 14 14 11...
Страница 585: ...Chapter 15 Self Diagnosis...
Страница 586: ......
Страница 588: ......
Страница 623: ...Chapter 16 Service Mode...
Страница 624: ......
Страница 626: ......
Страница 679: ...Chapter 17 Upgrading...
Страница 680: ......
Страница 682: ......
Страница 693: ...Chapter 17 17 11 F 17 18 2 Click Start F 17 19 3 When the session has ended click OK...
Страница 698: ...Chapter 17 17 16 F 17 28 2 Click Start F 17 29 3 When the session has ended click OK...
Страница 710: ...Chapter 17 17 28 F 17 51 3 Click Start F 17 52 4 Click Save...
Страница 712: ...Chapter 17 17 30 F 17 55 2 Select the data to download F 17 56 3 Click Start...
Страница 714: ......
Страница 715: ...Chapter 18 Service Tools...
Страница 716: ......
Страница 717: ...Contents Contents 18 1 Service Tools 18 1 18 1 1 Special Tools 18 1 18 1 2 Oils and Solvents 18 1...
Страница 718: ......
Страница 720: ......
Страница 721: ...Jan 17 2007...
Страница 722: ......