background image

Facility Requirements Guide

Original Instructions

Copyright © 2013-2014 by 3D Systems Corporation. All rights reserved, SLA, Accura, and the 3D logo are registered trademarks of 3D Systems, 

Inc. Specifications subject to change without notice. ProX™, 3DManage™, 3DPrint™, Lightyear, ProCure, iPro, Zephyr, QuickCast, and Viper are 

trademarks.

www.3Dsystems.com

ProX™ 950

3D Production Printer

Содержание ProX 950

Страница 1: ...orporation All rights reserved SLA Accura and the 3D logo are registered trademarks of 3D Systems Inc Specifications subject to change without notice ProX 3DManage 3DPrint Lightyear ProCure iPro Zephy...

Страница 2: ...n of 3D Systems CONTENTS INTRODUCTION 1 ProX 950 1 Material Delivery Module MDM 1 Manual Offload Cart 2 ProCure UV Curing Chamber 2 CONTROLLER PART PREPARATION SOFTWARE 2 SITE SELECTION PROX 950 3 Spa...

Страница 3: ...sposal 14 Storage and Usage Guidelines 14 APPENDIX A INITIAL SITE SURVEY CHECKLIST 15 APPENDIX B PRE INSTALLATION PREPARATION CHECKLIST 16 Moving Equipment and Site Accessibility 16 SLA System Area 16...

Страница 4: ...ments for installing the ProX 950 in your facility Resin Storage and Safety gives you guidelines for proper storage handling and safety for SLA resins PROX 950 The ProX 950 is a flexible and efficient...

Страница 5: ...ystem the part is placed in this unit Subjecting the part s to UV light for a period of time will fully solidify the part After the part is removed from the unit adequately washed and rinsed it is ful...

Страница 6: ...ided during service calls Figure 6 Optimal Site Layout top view FLOOR AREA SURFACE Floors and counter spaces in the SLA work area should be non porous and suitable for cleaning with solvents The feet...

Страница 7: ...s front view 219 96cm 86 6 in Facility Wall 60cm 24 in 159cm 62 6 in 80 01cm 31 5 in 160 02cm 63 in 93 99cm 37 in 93 99cm 37 in 219 96cm 86 6 in 160 02cm 63 in 80 01cm 31 5 in 219 96cm 86 6 in Facilit...

Страница 8: ...sired backup time The manufacturer can recommend an appropriate model HEAT DISSIPATION The ProX 950 dissipates as much as 4580W of heat while printing and as much as 2600W while idle CONNECTION TO AC...

Страница 9: ...Pro X 950 System External Enclosure 110 N cm2 160 psi MDM 750F 324 N cm2 470 psi Exact total lled weight depends on material 3 8 cm 1 5 in 12 7 mm 0 5 in 10 cm 4 in MDM 208 cm 81 9 in 192 cm 75 6 in...

Страница 10: ...other employees or personnel during installation or future service calls A separate room or area that can be closed to others is necessary The system is safe and does not present hazards to properly t...

Страница 11: ...rge protected circuit We strongly recommend an Uninterruptible Power Supply UPS in areas with frequent power fluctuations surges and spikes can damage electronic components and power loss can damage t...

Страница 12: ...9 3D Systems Inc Figure 12 ProCure 1500 UV Chamber Dimensions 193 2 cm 76 06 in 112 55 cm 44 31 in 157 81 cm 62 13 in 97 16 cm 38 25 in...

Страница 13: ...ems if crates are opened without an authorized 3D Systems employee present supervising this procedure Inform your receiving personnel that these crates will be arriving and arrange for a location to s...

Страница 14: ...inspection receive the crates The following chart lists both crated and uncrated dimensions and weights for every possible crate that you may have ordered Verify your order and compare to the listed...

Страница 15: ...es see accompanying sidebar for a complete list Safety equipment see sidebar One or more Windows XP Professional Vista or Windows 7 equipped workstations At least one system must be available at insta...

Страница 16: ...mponents Do not allow the system weight load to exceed your floor s load rating maximum AVAILABILITY FOR ADEQUATE FORKLIFT OR LIFTING EQUIPMENT You must have a forklift and a trained forklift driver a...

Страница 17: ...cility Do not leave uncured or liquid resins in an area where persons who are not knowledgeable about their handling or use may have access to them If your area requires a regulated waste disposal con...

Страница 18: ...riate non condensing level for the SLA material 20 50 See page 6 Is adequate electrical power available to the site Are there at least two 220 V circuits two outlets each with its own circuit and at l...

Страница 19: ...and locked during installation Is there a network connection Optional Is there a telephone line Optional MOVING EQUIPMENT AND SITE ACCESSIBILITY Is adequate space available for the equipment and suppl...

Страница 20: ...TPM Wash Unit MK36CSSX WRU Water Rinse Unit SA WRU Water Recycling Unit Web Cam Panasonic Model KX HCM280 is recommended Uninterruptible Power Supply American Power Conversion or Toshiba 5KVA Hand He...

Страница 21: ...n K K 4 6 8 Tsurumaki Setagaya ku Tokyo 154 0016 JAPAN General Inquiries 81 3 5451 1690 Material Orders 81 3 5451 1690 Customer Support 81 3 5451 1690 E mail japaninfo 3dsystems com U K 3D Systems Eur...

Страница 22: ...roCure 750UV Chamber 2 Figure 5 Part Preparation Software 2 Figure 6 Optimal Site Layout 3 Figure 7b ProX 950 system space requirements top view 4 Figure 8b ProX 950 system space requirements front vi...

Страница 23: ...k Access 7 O Optional equipment includes 12 P Part Finishing Area 16 Part Washing Systems 17 Preparation for Receiving 10 Preparing for System Installation 13 ProCure UVCuring Chamber 2 ProX 950 SLA C...

Страница 24: ...land 18 System De crating 13 System Delivery 1 10 System Installation 1 13 T Telephone Service 7 Temperature 5 Third Party Equipment and Supplies 1 Third Party Supplies and Equipment 12 17 Transportin...

Страница 25: ...3D Systems Inc 333 Three D Systems Circle Rock Hill SC 29730 www 3dsystems com 2016 3D Systems Inc All rights reserved P n 285393 00 Rev C...

Отзывы: