Chapter 15
15-11
*4
01
The ongoing write operation has been
suspended (at startup).
1. Set '0' for TYPE-TYPE, and execute HDD-
CHECK (40 to 50 min). Thereafter, turn off and
then back on the power.
2. If the symptom still exits after the foregoing,
execute HDD-CLEAR using TYPE-TYPE=1, 2, 3,
5. Thereafter, turn off and then back on the power.
*5
02
A file system error has occurred.
1. Type in TYPE-TYPE of the partition in
question, and execute HDD-CLEAR. Thereafter,
turn off and then back on the main switch.
2. If the system still exits after the foregoing,
suspect a fault on the HDD, and replace the HDD
and re-install the system software.
*6
02
There is a file system error.
The system software is designed so that the
information in this partition (e.g., address book,
filter) is not deleted inadvertently; i.e., you will not
the able to execute HDD-CLEAR from service
mode.
1. If possible, ask the user to back up the address
book data using the RUI.
2. From service mode, start download mode; then,
execute full formatting using the SST and re-install
the system software (System, Language, RUI).
Thereafter, turn off and the back on the main
power.
*7
02
A file system error has occurred.
This type of error is highly rare.
1. Using TYPE-TYPE=1, 2, 3, 5, execute HDD-
CLEAR. Thereafter, turn off and then back on the
power.
2. If the symptom still exits after the foregoing,
suspect a fault on the HDD, and replace the HDD
and re-install the system software.
*8
02
A file system error has occurred.
The system software is designed so that a recovery
session will not run for the boot partition unless
you use safe mode in combination with the SST.
1. Start up in safe mode, and execute full
formatting using the SST and re-install the system
software (System, Language, RUI). Thereafter,
turn off and then on the main power.
2. If the symptom still exits after the foregoing,
suspect a fault on the HDD, and replace the HDD
and re-install the system software.
*9
03
There is poor contact of the HDD, or
a v.x Works system error has
occurred.
1. Check the cable and power supply connectors.
2. If the symptom still exits after the foregoing,
start up in safe mode, and execute full formatting
using the SST and re-install the system software
(System, Language, RUI). Thereafter, turn off and
then back on the main power.
3. If the symptom still exits after the foregoing,
suspect a fault on the HDD, and replace the HDD
and re-install the system software.
*10
11,21
The HDD has poor contact.
This type of error is highly rare in relation to read/
write operations.
1. Check the cable and the power supply
connectors.
2.If the symptom still exits after the foregoing,
suspect a fault on the HDD, and replace the HDD
and install the system software.
*11
13, 25
The ongoing write operation has been
suspended.
There is a likelihood of the presence of damage to
the file data on the HDD (e.g., Box).
1. Set '0' for TYPE-TYPE, and execute HDD-
CHECK (40 to 50 min). Thereafter, turn off and
then back on the power.
2. If the symptom still exits after the foregoing, set
'1' for TYPE-TYPE, and execute HDD-CLEAR.
(In the case of DOSDEV4 or BOOTDEV, execute
formatting and re-installation once again.)
3. If the symptom still exists after the foregoing,
suspect a fault on the HDD, and replace the HDD
and re-install the system software.
*12
10, 12, 14, 22,
23, 24
There is a system error or a packet
data error.
The data may be corrupted or there is a software
bug.
1. Start up in safe mode, and execute full
formatting using the SST and re-install the system
software (System, Language, RUI). Thereafter,
turn off and then back on the main power.
2. If the symptom still exits after the foregoing,
suspect a fault on the HDD, and replace the HDD
and re-install the system software.
YY
Description
Remedy
Содержание iR3570 Series
Страница 1: ...Jan 17 2007 Service Manual iR4570 3570 2870 2270 Series...
Страница 2: ......
Страница 6: ......
Страница 27: ...Chapter 1 Introduction...
Страница 28: ......
Страница 70: ......
Страница 71: ...Chapter 2 Installation...
Страница 72: ......
Страница 146: ......
Страница 147: ...Chapter 3 Basic Operation...
Страница 148: ......
Страница 150: ......
Страница 154: ......
Страница 155: ...Chapter 4 Main Controller...
Страница 156: ......
Страница 187: ...Chapter 5 Original Exposure System...
Страница 188: ......
Страница 217: ...Chapter 5 5 27 F 5 91...
Страница 218: ......
Страница 219: ...Chapter 6 Laser Exposure...
Страница 220: ......
Страница 222: ......
Страница 230: ......
Страница 231: ...Chapter 7 Image Formation...
Страница 232: ......
Страница 236: ......
Страница 279: ...Chapter 7 7 43 F 7 241 2 Remove the screw 1 F 7 242 3 Detach the static eliminator 1 to the front F 7 243...
Страница 280: ......
Страница 281: ...Chapter 8 Pickup Feeding System...
Страница 282: ......
Страница 388: ......
Страница 389: ...Chapter 9 Fixing System...
Страница 390: ......
Страница 419: ...Chapter 9 9 27 F 9 148...
Страница 420: ......
Страница 421: ...Chapter 10 External and Controls...
Страница 422: ......
Страница 426: ......
Страница 437: ...Chapter 10 10 11 F 10 12 2 Remove the check mark from SNMP Status Enabled...
Страница 438: ...Chapter 10 10 12 F 10 13...
Страница 440: ...Chapter 10 10 14 F 10 15...
Страница 475: ...Chapter 11 MEAP...
Страница 476: ......
Страница 478: ......
Страница 481: ...Chapter 12 Maintenance and Inspection...
Страница 482: ......
Страница 484: ......
Страница 509: ...Chapter 13 Standards and Adjustments...
Страница 510: ......
Страница 512: ......
Страница 521: ...Chapter 14 Correcting Faulty Images...
Страница 522: ......
Страница 528: ......
Страница 537: ...Chapter 14 14 9 43mm s b Z x i j B iR4570_395 s u A B FM2 0287...
Страница 538: ...Chapter 14 14 10...
Страница 539: ...Chapter 14 14 11...
Страница 585: ...Chapter 15 Self Diagnosis...
Страница 586: ......
Страница 588: ......
Страница 623: ...Chapter 16 Service Mode...
Страница 624: ......
Страница 626: ......
Страница 679: ...Chapter 17 Upgrading...
Страница 680: ......
Страница 682: ......
Страница 693: ...Chapter 17 17 11 F 17 18 2 Click Start F 17 19 3 When the session has ended click OK...
Страница 698: ...Chapter 17 17 16 F 17 28 2 Click Start F 17 29 3 When the session has ended click OK...
Страница 710: ...Chapter 17 17 28 F 17 51 3 Click Start F 17 52 4 Click Save...
Страница 712: ...Chapter 17 17 30 F 17 55 2 Select the data to download F 17 56 3 Click Start...
Страница 714: ......
Страница 715: ...Chapter 18 Service Tools...
Страница 716: ......
Страница 717: ...Contents Contents 18 1 Service Tools 18 1 18 1 1 Special Tools 18 1 18 1 2 Oils and Solvents 18 1...
Страница 718: ......
Страница 720: ......
Страница 721: ...Jan 17 2007...
Страница 722: ......