Chapter 16
16-19
F-16-16
<CCD>
T-16-18
<LASER>
T-16-19
<DEVELOP>
T-16-20
<DENS>
COPIER > ADJUST > CCD
Sub-item
Desciption
Level
MTF-MG
Entering a main-scan MTF correction value
1
<Setting range>
0 to 99 (Default: 0)
- If the CIS unit has been replaced, enter the value from the label affixed to the CIS
unit.
- If RAM on the reader controller circuit board has been cleared or the board itself has
been replaced, enter the value from the service label.
- If the setting of this item has been changed, enter the new value into the service label.
MTF-SG
Not used
1
DFTAR-R
Entering a shading target value (red) when DF is in use (Ordinary document read
position)
1
<Setting range>
1 to 2047 (Default: 1106)
If an image error (attributable to a dirty chart or other) has occurred after the execution
of COPIER>FUNCTION>DF-WLVL1/DF-WLVL2, enter factory measurement data
in this mode.
DFTAR2-R
Entering a shading target value (red) when DF is in use (Secondary document read
position)
1
<Setting range>
1 to 2047 (Default: 1138)
If an image error (attributable to a dirty chart or other) has occurred after the execution
of COPIER>FUNCTION>DF-WLVL2, enter factory measurement data in this mode.
SH-TRGT
Entry of a white level target value at the time of shading correction
1
<Setting range>
1 to 2046 Default: 1070
As a remedy in the field, a shade on an image occurring when a folded/creased
document is read is lessened.
COPIER > ADJUST > LASER
Sub-item
Description
Level
LA-OFF
Adjusting the rear-end laser OFF position
1
<Setting range> -128 to 127 (Default: 0)
If RAM on the DC controller circuit board has been cleared or the board itself has
been replaced, enter the value from the service label.
LA-DELAY
Entering a delay value after laser unit displacement (Matching the laser main scan)
1
<Setting range>
360 to 440
Enter the delay value peculiar to the unit affixed to the unit at laser unit
replacement.
POWER
Adjusting the laser power
1
<Setting range>
-128 to 127 (Default: 0)
If RAM on the DC controller circuit board has been cleared or the board itself has
been replaced, enter the value from the service label.
COPIER > ADJUST > DEVELOP
Sub-item
Description
Level
DE-OFST
Entering an offset value for the developing bias DC
1
<Setting range>
-128 to 127 (Default: 0)
Setting a greater value increases the density.
Original
Read start position
Decrease the setting
(so that the read start
position moves toward the rear).
Increase the setting
(so that the read
start position moves
toward the front).
Содержание iR3570 Series
Страница 1: ...Jan 17 2007 Service Manual iR4570 3570 2870 2270 Series...
Страница 2: ......
Страница 6: ......
Страница 27: ...Chapter 1 Introduction...
Страница 28: ......
Страница 70: ......
Страница 71: ...Chapter 2 Installation...
Страница 72: ......
Страница 146: ......
Страница 147: ...Chapter 3 Basic Operation...
Страница 148: ......
Страница 150: ......
Страница 154: ......
Страница 155: ...Chapter 4 Main Controller...
Страница 156: ......
Страница 187: ...Chapter 5 Original Exposure System...
Страница 188: ......
Страница 217: ...Chapter 5 5 27 F 5 91...
Страница 218: ......
Страница 219: ...Chapter 6 Laser Exposure...
Страница 220: ......
Страница 222: ......
Страница 230: ......
Страница 231: ...Chapter 7 Image Formation...
Страница 232: ......
Страница 236: ......
Страница 279: ...Chapter 7 7 43 F 7 241 2 Remove the screw 1 F 7 242 3 Detach the static eliminator 1 to the front F 7 243...
Страница 280: ......
Страница 281: ...Chapter 8 Pickup Feeding System...
Страница 282: ......
Страница 388: ......
Страница 389: ...Chapter 9 Fixing System...
Страница 390: ......
Страница 419: ...Chapter 9 9 27 F 9 148...
Страница 420: ......
Страница 421: ...Chapter 10 External and Controls...
Страница 422: ......
Страница 426: ......
Страница 437: ...Chapter 10 10 11 F 10 12 2 Remove the check mark from SNMP Status Enabled...
Страница 438: ...Chapter 10 10 12 F 10 13...
Страница 440: ...Chapter 10 10 14 F 10 15...
Страница 475: ...Chapter 11 MEAP...
Страница 476: ......
Страница 478: ......
Страница 481: ...Chapter 12 Maintenance and Inspection...
Страница 482: ......
Страница 484: ......
Страница 509: ...Chapter 13 Standards and Adjustments...
Страница 510: ......
Страница 512: ......
Страница 521: ...Chapter 14 Correcting Faulty Images...
Страница 522: ......
Страница 528: ......
Страница 537: ...Chapter 14 14 9 43mm s b Z x i j B iR4570_395 s u A B FM2 0287...
Страница 538: ...Chapter 14 14 10...
Страница 539: ...Chapter 14 14 11...
Страница 585: ...Chapter 15 Self Diagnosis...
Страница 586: ......
Страница 588: ......
Страница 623: ...Chapter 16 Service Mode...
Страница 624: ......
Страница 626: ......
Страница 679: ...Chapter 17 Upgrading...
Страница 680: ......
Страница 682: ......
Страница 693: ...Chapter 17 17 11 F 17 18 2 Click Start F 17 19 3 When the session has ended click OK...
Страница 698: ...Chapter 17 17 16 F 17 28 2 Click Start F 17 29 3 When the session has ended click OK...
Страница 710: ...Chapter 17 17 28 F 17 51 3 Click Start F 17 52 4 Click Save...
Страница 712: ...Chapter 17 17 30 F 17 55 2 Select the data to download F 17 56 3 Click Start...
Страница 714: ......
Страница 715: ...Chapter 18 Service Tools...
Страница 716: ......
Страница 717: ...Contents Contents 18 1 Service Tools 18 1 18 1 1 Special Tools 18 1 18 1 2 Oils and Solvents 18 1...
Страница 718: ......
Страница 720: ......
Страница 721: ...Jan 17 2007...
Страница 722: ......