Chapter 9
9-2
9.2.2 Down Sequence
0006-6007
iR2270 / iR2870 / iR3570 / iR4570 / / iR2270N / / iR2870N / / iR3570N / / iR4570N / iR2230 / / / iR3530 /
Down sequence is to prevent the machine from operating when the temperature of the end portion of the fixing film exceeds a specific temperature as when using
small-size paper continuously. The details of the control are described below:
1. The sub thermistor detection temperature is 275 deg C or more.
2. Reduces the number of sheets passed by increasing the paper interval.
3. Returns the number of sheets to the normal when the sub thermistor detection temperature is 265 deg C or less.
9.3 Various Control Mechanisms
9.3.1 Controlling the Speed of the Fixing Film
9.3.1.1 Controlling the Fixing Film Speed in Response to Low Temperature
0006-6037
iR2270 / iR2870 / iR3570 / iR4570 / / iR2270N / / iR2870N / / iR3570N / / iR4570N / iR2230 / / / iR3530 /
As in the morning, driving the fixing film in a low-temperature environment without warm-up could cause the film to become displaced. In consideration of this
fact, the fixing motor is started up in phases (1/4 speed to 1/2 speed and then to normal speed).
9.3.1.2 Controlling the Fixing Film Speed
0007-5124
iR2270 / iR2870 / iR3570 / iR4570 / / iR2270N / / iR2870N / / iR3570N / / iR4570N / iR2230 / / / iR3530 /
The rotation cycle of the fixing film is monitored to control the fixing motor to a specific speed.
When the fixing film rotates and, as a result, the reflecting member positioned in the loop of the film approaches the speed sensor, the machine detects the rotation
of the fixing film.
F-9-2
[1]Speed sensor
[2]Reflecting member
[3]Fixing film (driven by fixing motor)
[4]Pressure roller
[A]Paper feed direction
[B]Speed sensor output
[C]1 rotation of fixing film
Timing of Control
The speed of fixing film rotation is monitored at all times after the fixing motor goes on and its speed reaches a specific value. The speed of the fixing motor is then
controlled so that it remains at a specific level at all times.
9.3.2 Controlling the Fixing Film Temperature
9.3.2.1 Controlling the Power Supply in Response to Low Temperature
0007-5125
iR2270 / iR2870 / iR3570 / iR4570 / / iR2270N / / iR2870N / / iR3570N / / iR4570N / iR2230 / / / iR3530 /
In a low temperature environment, the heater is supplied with power before the fixing film is driven so as to soften the grease applied to the fixing film. The mech-
anism of control is as follows:
If the temperature of the fixing film detected by the thermistor is lower than a specific level, the heater is supplied with power for a specific period of time before
a normal start-up mechanism is initiated.
If the temperature of the fixing film detected by the thermistor is higher than a specific level, the normal start-up mechanism is imitated.
9.3.2.2 Controlling the Feeding in Response to Low Temperature
0007-5401
iR2270 / iR2870 / iR3570 / iR4570 / / iR2270N / / iR2870N / / iR3570N / / iR4570N / iR2230 / / / iR3530 /
In a low temperature environment, the feeding timing is changed according to the temperature detected by the environment sensor so as to enhance the fixing ca-
pability. The details are described below.
When the environment sensor detection temperature is 13 deg C or less, the feeding timing is delayed by 5000 msec.
In thick paper mode, the feeding timing is not changed even if the environment sensor detection temperature is 13 deg C or less.
9.3.2.3 Controlling the Power Supply at Start-Up
0006-6583
iR2270 / iR2870 / iR3570 / iR4570 / / iR2270N / / iR2870N / / iR3570N / / iR4570N / iR2230 / / / iR3530 /
When the thermistor detection temperature is 180 deg C or less, the power control to compensate for the heater, (varying according to input voltage and a heater
resistor value) is performed so as to raise the temperature of the fixing unit to the required temperature for fixing in a short time.
1. starts 65% power supply.
[C]
[2]
[B]
[A]
Off
On
[4]
[1]
[3]
Содержание iR3570 Series
Страница 1: ...Jan 17 2007 Service Manual iR4570 3570 2870 2270 Series...
Страница 2: ......
Страница 6: ......
Страница 27: ...Chapter 1 Introduction...
Страница 28: ......
Страница 70: ......
Страница 71: ...Chapter 2 Installation...
Страница 72: ......
Страница 146: ......
Страница 147: ...Chapter 3 Basic Operation...
Страница 148: ......
Страница 150: ......
Страница 154: ......
Страница 155: ...Chapter 4 Main Controller...
Страница 156: ......
Страница 187: ...Chapter 5 Original Exposure System...
Страница 188: ......
Страница 217: ...Chapter 5 5 27 F 5 91...
Страница 218: ......
Страница 219: ...Chapter 6 Laser Exposure...
Страница 220: ......
Страница 222: ......
Страница 230: ......
Страница 231: ...Chapter 7 Image Formation...
Страница 232: ......
Страница 236: ......
Страница 279: ...Chapter 7 7 43 F 7 241 2 Remove the screw 1 F 7 242 3 Detach the static eliminator 1 to the front F 7 243...
Страница 280: ......
Страница 281: ...Chapter 8 Pickup Feeding System...
Страница 282: ......
Страница 388: ......
Страница 389: ...Chapter 9 Fixing System...
Страница 390: ......
Страница 419: ...Chapter 9 9 27 F 9 148...
Страница 420: ......
Страница 421: ...Chapter 10 External and Controls...
Страница 422: ......
Страница 426: ......
Страница 437: ...Chapter 10 10 11 F 10 12 2 Remove the check mark from SNMP Status Enabled...
Страница 438: ...Chapter 10 10 12 F 10 13...
Страница 440: ...Chapter 10 10 14 F 10 15...
Страница 475: ...Chapter 11 MEAP...
Страница 476: ......
Страница 478: ......
Страница 481: ...Chapter 12 Maintenance and Inspection...
Страница 482: ......
Страница 484: ......
Страница 509: ...Chapter 13 Standards and Adjustments...
Страница 510: ......
Страница 512: ......
Страница 521: ...Chapter 14 Correcting Faulty Images...
Страница 522: ......
Страница 528: ......
Страница 537: ...Chapter 14 14 9 43mm s b Z x i j B iR4570_395 s u A B FM2 0287...
Страница 538: ...Chapter 14 14 10...
Страница 539: ...Chapter 14 14 11...
Страница 585: ...Chapter 15 Self Diagnosis...
Страница 586: ......
Страница 588: ......
Страница 623: ...Chapter 16 Service Mode...
Страница 624: ......
Страница 626: ......
Страница 679: ...Chapter 17 Upgrading...
Страница 680: ......
Страница 682: ......
Страница 693: ...Chapter 17 17 11 F 17 18 2 Click Start F 17 19 3 When the session has ended click OK...
Страница 698: ...Chapter 17 17 16 F 17 28 2 Click Start F 17 29 3 When the session has ended click OK...
Страница 710: ...Chapter 17 17 28 F 17 51 3 Click Start F 17 52 4 Click Save...
Страница 712: ...Chapter 17 17 30 F 17 55 2 Select the data to download F 17 56 3 Click Start...
Страница 714: ......
Страница 715: ...Chapter 18 Service Tools...
Страница 716: ......
Страница 717: ...Contents Contents 18 1 Service Tools 18 1 18 1 1 Special Tools 18 1 18 1 2 Oils and Solvents 18 1...
Страница 718: ......
Страница 720: ......
Страница 721: ...Jan 17 2007...
Страница 722: ......