Appendix A. CRBasic Programming Instructions
456
PeakValley
Detects
maxima
and
minima
in
a
signal.
Syntax
PeakValley(DestPV, DestChange, Reps, Source, Hysteresis)
Sample
Stores
the
current
value
at
the
time
of
output.
Syntax
Sample(Reps, Source, DataType)
SampleFieldCal
Writes
field
calibration
data
to
a
table.
See
Calibration
Functions
(p.
500
).
SampleMaxMin
Samples
a
variable
when
another
variable
reaches
its
maximum
or
minimum
for
the
defined
output
period.
Syntax
SampleMaxMin(Reps, Source, DataType, DisableVar)
StdDev
Calculates
the
standard
deviation
over
the
output
interval.
Syntax
StdDev(Reps, Source, DataType, DisableVar)
Totalize
Sums
the
total
over
the
output
interval.
Syntax
Totalize(Reps, Source, DataType, DisableVar)
A.2.3.2 Multiple-Source
ETsz
Stores
evapotranspiration
(ETsz)
and
solar
radiation
(RSo).
Syntax
ETsz(Temp, RH, uZ, Rs, Longitude, Latitude, Altitude, Zw, Sz,
DataType, DisableVar)
RainFlowSample
Stores
a
sample
of
the
CDM_VW300RainFlow
into
a
data
table.
Syntax
RainFlowSampe(Source, DataType)
WindVector
Processes
wind
speed
and
direction
from
either
polar
or
orthogonal
sensors.
To
save
processing
time,
only
calculations
resulting
in
the
requested
data
are
performed.
Syntax
WindVector(Repetitions, Speed/East, Direction/North,
DataType, DisableVar, Subinterval, SensorType, OutputOpt)
Read More!
See
Wind Vector
(p. 189).
Содержание CR850
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 26: ...Table of Contents 26...
Страница 30: ...Section 2 Cautionary Statements 30...
Страница 32: ...Section 3 Initial Inspection 32...
Страница 35: ...Section 4 Quickstart Tutorial 35 Figure 2 Wiring panel...
Страница 55: ...Section 4 Quickstart Tutorial 55 Figure 24 PC200W View data utility...
Страница 78: ...Section 5 System Overview 78...
Страница 80: ...Section 6 CR800 Specifications 80...
Страница 95: ...Section 7 Installation 95 Figure 35 DevConfig OS download window Figure 36 Dialog box confirming OS download...
Страница 104: ...Section 7 Installation 104 Figure 43 Include File settings via DevConfig Figure 44 Include File settings via PakBusGraph...
Страница 267: ...Section 7 Installation 267 Figure 84 Running average signal attenuation...
Страница 268: ...Section 7 Installation 268...
Страница 384: ...Section 8 Operation 384 Figure 113 Using the keyboard display...
Страница 385: ...Section 8 Operation 385 8 8 1 Data Display Figure 114 Displaying data with the keyboard display...
Страница 387: ...Section 8 Operation 387 Figure 116 Real time custom...
Страница 388: ...Section 8 Operation 388 8 8 1 3 Final Storage Tables Figure 117 Final storage tables...
Страница 389: ...Section 8 Operation 389 8 8 2 Run Stop Program Figure 118 Run Stop Program...
Страница 390: ...Section 8 Operation 390 8 8 3 File Display Figure 119 File display...
Страница 396: ...Section 8 Operation 396...
Страница 402: ...Section 9 Maintenance 402...
Страница 450: ...Section 11 Glossary 450...
Страница 504: ...Appendix A CRBasic Programming Instructions 504...
Страница 526: ...Appendix B Status Table and Settings 526...
Страница 530: ...Appendix C Serial Port Pinouts 530...
Страница 536: ...Appendix E FP2 Data Format 536...
Страница 550: ...Appendix F Other Campbell Scientific Products 550...
Страница 564: ...Index 564 WriteIO 464 Writing Program 108 X XML 448 XOR 473 Y Y intercept 141 142 Z Zero 155 166 Zero Basis 151...
Страница 565: ......