Section 7. Installation
220
'///////////////Serial Time Set Input Section///////////////
'Accept old C command -- [2008:028:10:36:22]C -- parse, process, set
'clock (Note: Chr(91) = "[", Chr(67) = "C")
SerialInRecord
(ComRS232,InString,91,0,67,InStringSize,01)
If
InStringSize <> 0
Then
SplitStr
(InStringSplit,InString,"",5,0)
Call
DOY2MODAY
'Call subroutine to convert day-of-year
'to month & day
ClkSet(1) = Year
ClkSet(2) = Month
ClkSet(3) = Date
ClkSet(4) = Hour
ClkSet(5) = Minute
ClkSet(6) = Second
ClkSet(7) = uSecond
'Note: ClkSet array requires year, month, date, hour, min, sec, msec
ClockSet
(ClkSet())
CallTable
(ClockSetRecord)
EndIf
'/////////////////Serial Output Section/////////////////////
'Construct old Campbell Scientific Printable ASCII data format and output to COM1
'Read datalogger clock
RealTime
(rTime)
If
TimeIntoInterval
(0,5,Sec)
Then
'Load OneMinData table data for processing into printable ASCII
GetRecord
(OneMinData(),OneMinTable,1)
'/- Sign
For
i=1
To
6
If
OneMinData(i) < 0
Then
'Note: chr45 is - sign
OutFrag(i)=CHR(45) &
FormatFloat
(
ABS
(OneMinData(i)),"%05g")
Else
'Note: chr43 is + sign
OutFrag(i)=CHR(43) &
FormatFloat
(
ABS
(OneMinData(i)),"%05g")
EndIf
Next
i
'Concatenate Printable ASCII string, then push string out RS-232
'(first 2 fields are ID, hhmm):
OutString = "01+0115." & " 02+" &
FormatFloat
(rTime(4),"%02.0f") & _
FormatFloat
(rTime(5),"%02.0f")
OutString = OutString & " 03" & OutFrag(1) & " 04" & OutFrag(2) & _
" 05" & OutFrag(3)
OutString = OutString & " 06" & OutFrag(4) & " 07" & OutFrag(5) & _
CHR(13) & CHR(10) & ""
'add CR LF null
'Send printable ASCII string out RS-232 port
SerialOut
(ComRS232,OutString,"",0,220)
EndIf
NextScan
EndProg
Содержание CR850
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 26: ...Table of Contents 26...
Страница 30: ...Section 2 Cautionary Statements 30...
Страница 32: ...Section 3 Initial Inspection 32...
Страница 35: ...Section 4 Quickstart Tutorial 35 Figure 2 Wiring panel...
Страница 55: ...Section 4 Quickstart Tutorial 55 Figure 24 PC200W View data utility...
Страница 78: ...Section 5 System Overview 78...
Страница 80: ...Section 6 CR800 Specifications 80...
Страница 95: ...Section 7 Installation 95 Figure 35 DevConfig OS download window Figure 36 Dialog box confirming OS download...
Страница 104: ...Section 7 Installation 104 Figure 43 Include File settings via DevConfig Figure 44 Include File settings via PakBusGraph...
Страница 267: ...Section 7 Installation 267 Figure 84 Running average signal attenuation...
Страница 268: ...Section 7 Installation 268...
Страница 384: ...Section 8 Operation 384 Figure 113 Using the keyboard display...
Страница 385: ...Section 8 Operation 385 8 8 1 Data Display Figure 114 Displaying data with the keyboard display...
Страница 387: ...Section 8 Operation 387 Figure 116 Real time custom...
Страница 388: ...Section 8 Operation 388 8 8 1 3 Final Storage Tables Figure 117 Final storage tables...
Страница 389: ...Section 8 Operation 389 8 8 2 Run Stop Program Figure 118 Run Stop Program...
Страница 390: ...Section 8 Operation 390 8 8 3 File Display Figure 119 File display...
Страница 396: ...Section 8 Operation 396...
Страница 402: ...Section 9 Maintenance 402...
Страница 450: ...Section 11 Glossary 450...
Страница 504: ...Appendix A CRBasic Programming Instructions 504...
Страница 526: ...Appendix B Status Table and Settings 526...
Страница 530: ...Appendix C Serial Port Pinouts 530...
Страница 536: ...Appendix E FP2 Data Format 536...
Страница 550: ...Appendix F Other Campbell Scientific Products 550...
Страница 564: ...Index 564 WriteIO 464 Writing Program 108 X XML 448 XOR 473 Y Y intercept 141 142 Z Zero 155 166 Zero Basis 151...
Страница 565: ......