![Campbell CR850 Скачать руководство пользователя страница 446](http://html1.mh-extra.com/html/campbell/cr850/cr850_operators-manual_3829356446.webp)
Section 11. Glossary
446
terminal
emulator
A
command
‐
line
shell
that
facilitates
the
issuance
of
low
‐
level
commands
to
a
datalogger
or
some
other
compatible
device.
A
terminal
emulator
is
available
in
most
datalogger
support
software
available
from
Campbell
Scientific.
thermistor
A
thermistor
is
a
resistive
element
whose
change
in
resistance
with
temperature
is
wide,
stable,
and
well
‐
characterized.
It
can
be
used
as
a
device
to
measure
temperature.
The
output
of
a
thermistor
is
usually
non
‐
linear,
so
measurement
requires
linearization,
usually
by
means
of
the
Steinhart
‐
Hart
or
another
polynomial
equation.
Campbell
Scientific
thermistors,
models
107,
108,
and
109,
are
linearized
by
Steinhart
‐
Hart
as
implemented
in
the
Therm107()
,
Therm108()
,
and
Therm109()
instructions.
throughput
The
throughput
rate
is
the
rate
at
which
a
measurement
can
be
taken,
scaled
to
engineering
units,
and
the
reading
stored
in
a
data
table.
The
CR800
has
the
ability
to
scan
sensors
at
a
rate
exceeding
the
throughput
rate.
The
primary
factor
affecting
throughput
rate
is
the
amount
of
processing
specified
by
the
user.
In
sequential
‐
mode
operation,
all
processing
called
for
by
an
instruction
must
be
completed
before
moving
on
to
the
next
instruction.
TTL
Transistor
‐
transistor
logic.
A
serial
protocol
using
0
Vdc
and
5
Vdc
as
logic
signal
levels.
TLS
Transport
layer
security.
An
Internet
communications
security
protocol.
toggle
To
reverse
the
current
power
state.
UINT2
Data
type
used
for
efficient
storage
of
totalized
pulse
counts,
port
status
(status
of
16
ports
stored
in
one
variable,
for
example)
or
integer
values
that
store
binary
flags.
Содержание CR850
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 26: ...Table of Contents 26...
Страница 30: ...Section 2 Cautionary Statements 30...
Страница 32: ...Section 3 Initial Inspection 32...
Страница 35: ...Section 4 Quickstart Tutorial 35 Figure 2 Wiring panel...
Страница 55: ...Section 4 Quickstart Tutorial 55 Figure 24 PC200W View data utility...
Страница 78: ...Section 5 System Overview 78...
Страница 80: ...Section 6 CR800 Specifications 80...
Страница 95: ...Section 7 Installation 95 Figure 35 DevConfig OS download window Figure 36 Dialog box confirming OS download...
Страница 104: ...Section 7 Installation 104 Figure 43 Include File settings via DevConfig Figure 44 Include File settings via PakBusGraph...
Страница 267: ...Section 7 Installation 267 Figure 84 Running average signal attenuation...
Страница 268: ...Section 7 Installation 268...
Страница 384: ...Section 8 Operation 384 Figure 113 Using the keyboard display...
Страница 385: ...Section 8 Operation 385 8 8 1 Data Display Figure 114 Displaying data with the keyboard display...
Страница 387: ...Section 8 Operation 387 Figure 116 Real time custom...
Страница 388: ...Section 8 Operation 388 8 8 1 3 Final Storage Tables Figure 117 Final storage tables...
Страница 389: ...Section 8 Operation 389 8 8 2 Run Stop Program Figure 118 Run Stop Program...
Страница 390: ...Section 8 Operation 390 8 8 3 File Display Figure 119 File display...
Страница 396: ...Section 8 Operation 396...
Страница 402: ...Section 9 Maintenance 402...
Страница 450: ...Section 11 Glossary 450...
Страница 504: ...Appendix A CRBasic Programming Instructions 504...
Страница 526: ...Appendix B Status Table and Settings 526...
Страница 530: ...Appendix C Serial Port Pinouts 530...
Страница 536: ...Appendix E FP2 Data Format 536...
Страница 550: ...Appendix F Other Campbell Scientific Products 550...
Страница 564: ...Index 564 WriteIO 464 Writing Program 108 X XML 448 XOR 473 Y Y intercept 141 142 Z Zero 155 166 Zero Basis 151...
Страница 565: ......