Section 7. Installation
113
7.7.3.2 Structure
Table
CRBasic Program Structure
(p. 113)
delineates CRBasic program structure.
CRBasic example
Program Structure
(p. 114)
demonstrates the proper structure of a
CRBasic program.
Table 9.
CRBasic Program Structure
Declarations
Define CR800 memory usage. Declare constants,
variables, aliases, units, and data tables.
Declare constants
List fixed constants.
Declare
Public
variables
List / dimension variables viewable during program
execution.
Dimension variables
List / dimension variables not viewable during
program execution.
Define
Alias
es
Assign aliases to variables.
Define
Units
Assign engineering units to variable (optional).
Units are strictly for documentation. The CR800
makes no use of Units nor checks Unit accuracy.
Define data tables.
Define stored data tables.
Process / store trigger
Set triggers when data should be stored. Triggers
may be a fixed interval, a condition, or both.
Table size
Set the size of a data table.
Other on-line storage devices
Send data to a Campbell Scientific mass-storage
media (USB: drive) if available.
Processing of data
List data to be stored in the data table, e.g. samples,
averages, maxima, minima, etc.
Processes or calculations repeated during program
execution can be packaged in a subroutine and
called when needed rather than repeating the code
each time.
Begin program
Begin program defines the beginning of statements
defining CR800 actions.
Set scan interval
The scan sets the interval for a series of
measurements.
Measurements Enter
measurements
to
make.
Processing
Enter any additional processing.
Call data table(s)
Declared data tables must be called to process and
store data.
Initiate controls
Check measurements and initiate controls if
necessary.
NextScan
Loop back to set scan and wait for the next scan.
End program
End program defines the ending of statements
defining CR800 actions.
Содержание CR850
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 26: ...Table of Contents 26...
Страница 30: ...Section 2 Cautionary Statements 30...
Страница 32: ...Section 3 Initial Inspection 32...
Страница 35: ...Section 4 Quickstart Tutorial 35 Figure 2 Wiring panel...
Страница 55: ...Section 4 Quickstart Tutorial 55 Figure 24 PC200W View data utility...
Страница 78: ...Section 5 System Overview 78...
Страница 80: ...Section 6 CR800 Specifications 80...
Страница 95: ...Section 7 Installation 95 Figure 35 DevConfig OS download window Figure 36 Dialog box confirming OS download...
Страница 104: ...Section 7 Installation 104 Figure 43 Include File settings via DevConfig Figure 44 Include File settings via PakBusGraph...
Страница 267: ...Section 7 Installation 267 Figure 84 Running average signal attenuation...
Страница 268: ...Section 7 Installation 268...
Страница 384: ...Section 8 Operation 384 Figure 113 Using the keyboard display...
Страница 385: ...Section 8 Operation 385 8 8 1 Data Display Figure 114 Displaying data with the keyboard display...
Страница 387: ...Section 8 Operation 387 Figure 116 Real time custom...
Страница 388: ...Section 8 Operation 388 8 8 1 3 Final Storage Tables Figure 117 Final storage tables...
Страница 389: ...Section 8 Operation 389 8 8 2 Run Stop Program Figure 118 Run Stop Program...
Страница 390: ...Section 8 Operation 390 8 8 3 File Display Figure 119 File display...
Страница 396: ...Section 8 Operation 396...
Страница 402: ...Section 9 Maintenance 402...
Страница 450: ...Section 11 Glossary 450...
Страница 504: ...Appendix A CRBasic Programming Instructions 504...
Страница 526: ...Appendix B Status Table and Settings 526...
Страница 530: ...Appendix C Serial Port Pinouts 530...
Страница 536: ...Appendix E FP2 Data Format 536...
Страница 550: ...Appendix F Other Campbell Scientific Products 550...
Страница 564: ...Index 564 WriteIO 464 Writing Program 108 X XML 448 XOR 473 Y Y intercept 141 142 Z Zero 155 166 Zero Basis 151...
Страница 565: ......