Section 8. Operation
374
8.6.3.7 Files Management
Web API commands allow a web client to manage files on host CR800 memory
drives. Camera image files are examples of collections often needing frequent
management.
8.6.3.7.1 Sending a File to a Datalogger
A file can be sent to the CR800 using an
HTTPPut
request. Sending a file
requires a minimum
.csipasswd
access level of
1
(all access allowed). Unlike
other web API commands, originating a PUT request from a browser address bar
is not possible. Instead, use JavaScript within a web page or use the program
Curl.exe
.
Curl.exe
is available in the
LoggerNet RTMC
program files folder or at
http://curl.haxx.se. The
Curl.exe
command line takes the following form
(command line parameters are described in the accompanying table):
curl -XPUT -v -S -T "filename.ext" --user username:password
http://IPAdr/drive/
Table 97.
Curl HTTPPut Request Parameters
Parameter Description
-XPUT
Instructs
Curl.exe
to use the
HTTPPut
command
-v
Instructs
Curl.exe
to print all output to the screen
-S
Instructs
Curl.exe
to show errors
-T "filename.ext"
name of file to send to CR800 (enclose in quotes)
username
user name in the .csipasswrd file
password
password in the .csipasswrd file
IPAdr
IP address of the CR800
drive
memory drive of the CR800
Examples:
To load an operating system to the CR800, open a command prompt window
("DOS window") and execute the following command, as a continuous line:
curl -XPUT -v -S -T
"c:\campbellsci\lib\OperatingSystems\CR1000.Std.25.obj" --user
harrisonford:lostark1 http://192.168.24.106/cpu/
Response:
* About to connect() to 192.168.7.126 port 80 (#0)
* Trying 192.168.7.126... connected
* Connected to 192.168.7.126 (192.168.7.126) port 80 (#0)
* Server auth using Basic with user 'fredtest'
>PUT /cpu/myron%22Ecr1 HTTP/1.1
>Authorization: Basic ZGF2ZW1lZWs6d29vZnk5NTU1
>User-Agent: curl/7.21.1 (i386-pc-win32) libcurl/7.21.1
OpenSSL/0.9.8o zlib/1.2.5 libidn/1.18 libssh2/1.2.6
>Host: 192.168.7.126
>Accept:*/*
>Content-Length: 301
>Expect: 100-continue
>
Содержание CR850
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 26: ...Table of Contents 26...
Страница 30: ...Section 2 Cautionary Statements 30...
Страница 32: ...Section 3 Initial Inspection 32...
Страница 35: ...Section 4 Quickstart Tutorial 35 Figure 2 Wiring panel...
Страница 55: ...Section 4 Quickstart Tutorial 55 Figure 24 PC200W View data utility...
Страница 78: ...Section 5 System Overview 78...
Страница 80: ...Section 6 CR800 Specifications 80...
Страница 95: ...Section 7 Installation 95 Figure 35 DevConfig OS download window Figure 36 Dialog box confirming OS download...
Страница 104: ...Section 7 Installation 104 Figure 43 Include File settings via DevConfig Figure 44 Include File settings via PakBusGraph...
Страница 267: ...Section 7 Installation 267 Figure 84 Running average signal attenuation...
Страница 268: ...Section 7 Installation 268...
Страница 384: ...Section 8 Operation 384 Figure 113 Using the keyboard display...
Страница 385: ...Section 8 Operation 385 8 8 1 Data Display Figure 114 Displaying data with the keyboard display...
Страница 387: ...Section 8 Operation 387 Figure 116 Real time custom...
Страница 388: ...Section 8 Operation 388 8 8 1 3 Final Storage Tables Figure 117 Final storage tables...
Страница 389: ...Section 8 Operation 389 8 8 2 Run Stop Program Figure 118 Run Stop Program...
Страница 390: ...Section 8 Operation 390 8 8 3 File Display Figure 119 File display...
Страница 396: ...Section 8 Operation 396...
Страница 402: ...Section 9 Maintenance 402...
Страница 450: ...Section 11 Glossary 450...
Страница 504: ...Appendix A CRBasic Programming Instructions 504...
Страница 526: ...Appendix B Status Table and Settings 526...
Страница 530: ...Appendix C Serial Port Pinouts 530...
Страница 536: ...Appendix E FP2 Data Format 536...
Страница 550: ...Appendix F Other Campbell Scientific Products 550...
Страница 564: ...Index 564 WriteIO 464 Writing Program 108 X XML 448 XOR 473 Y Y intercept 141 142 Z Zero 155 166 Zero Basis 151...
Страница 565: ......