Installation in the pipe
Type 8098
7.4.2
Installing a device with clamp connections
The manufacturer of the device does not supply any gaskets for the process connections.
→
If the installation must be EHEDG-compliant and the device is fitted with clamp connections according
to ASME BPE (DIN 32676 series C), DIN 32676 series A, DIN 32676 series B or SMS 3017 / ISO 2852 for
pipes according to SMS 3008, use EHEDG-compliant gaskets from Combifit International B.V.
→
To make sure you use EHEDG-compliant gaskets, refer to the "EHEDG Position Paper" available on the
EHEDG website.
→
The clamp connections according to DIN 11864-3 series A, B and C are hygienic connections. You can
use any gaskets that are adapted to the process.
→
Make sure the gaskets on the clamp connections are in good condition.
→
Place gaskets adapted to the process (temperature, fluid type) in the grooves of the clamp connections.
→
Attach the clamp connections to the pipe with clamp collars. Make sure that tightening the clamp collar
does not create bulges at the gaskets.
7.4.3
Installing a device with flange connections
→
The flange connections according to DIN 11864-2 series A, B and C are hygienic connections. You can
use any gaskets that are adapted to the process.
→
Make sure the gaskets on the flange connections are in good condition.
→
Place gaskets adapted to the process (temperature, fluid type) in the flange connections.
→
Use bolts with dimensions as given in the relevant flange standard and adapted to the process.
→
Tighten the bolts to a torque as given in the relevant flange standard to fix the fitting to the pipe.