37
Installation in the pipe
Type 8098
→
To make sure the internal temperature of the transmitter does not exceed the authorized maximum value,
install the device as recommended in
.
Not recommended
Recommended
7)
Recommended
7)
7) These orientations are valid for all the positions of the Type SE91 transmitter on the
Type S097 flow sensor. Refer to Figure 9: Possible positions of the transmitter SE91
Figure 11:
Orientation of a device to avoid effects of high liquid temperatures
7.4
Installing the device into the pipe
CAUTION
Risk of injury due to a heavy device.
A heavy device can fall down during transport or during installation and cause injuries.
▶
Transport, install and dismantle a heavy device with the help of another person.
▶
Use appropriate tools.
7.4.1
Before installing the device into the pipe
→
Prepare the device as described in chpt.
7.2.
→
Follow the recommendations given in chpt.
English